HUNTER-PRO Series & CAPTAIN 8 User Guide
33
13
MANUAL SYSTEM TESTS (BACK KEY)
Master code
…
…
…
.
•
The system constantly tests the backup battery, the voltage and the phone line. However,
you can perform a manual test too.
•
A manual test is reported to the Monitoring Station.
•
If the tests fail, the following messages appear:
Ba t t e r y Te s t . .
L o w Ba t t e r y !
and/or
If your alarm system is connected to a Monitoring Station via Ethernet or GPRS,
some additional test screens are displayed.
14
REMOTE CONTROL VIA THE PHONE
•
Remote control is not available in Captain 8.
•
This section refers to Hunter-Pro Series only.
•
The Hunter-Pro Series alarm system can be remotely controlled via any touchtone or
cellular phone.
•
A remote control call can be initiated by both calling the panel and receiving a call
from the panel.
•
There are two modes to remote control (they are set by the Installer):
Basic mode: includes arming, disarming, deactivating the sirens, and more. That’s
the default mode;
Full mode: includes the basic mode and in addition, activating RELAY switches.
14.1
Basic mode
•
To control the system remotely:
1.
Call the phone number to which the system is connected (or pick a call from the system).
2.
Wait for a confirmation tone: a long tone followed by 2 beeps.
3.
Dial the Master code or authorized User code (see section 9.4);
4.
Wait for a status tone:
Continuous: The system is disarmed;
Beeps: The system is armed;
BACK
BACK
BACK
BACK
Ba t t e r y Te s t . .
Ba t t e r y Te s t . .
Fi n i s h e d OK!
Te s t i n g L i n e . . S1
Fi n i s h e d OK!
1 2 NOV 1 1 1 7: 1 5
Ph on e L i n e Fau l t