2. Attach the reflector to the mounting surface using two screws (M4).

Display and operator elements

[2]

[3]

[1]

[1]

Control for setting the sens-
itivity

To detect smaller objects, set the control to a lower
sensitivity (move control to the left).

To detect larger objects, set the control to a higher
sensitivity (move control to the right).

[2]

Yellow LED: Status indicator LED on: Light beam is interrupted

LED off: Light beam is not interrupted

[3]

Green LED: Operating
status and luminosity

LED on: Light beam is detected, device is ready for
operation

LED off: Light beam is not detected (caused by con-
taminations, for example), device is not ready for oper-
ation

LED goes out briefly when an object enters the light
beam

Содержание PSENop 3.3

Страница 1: ...PSENop 3 3 Operating Manual 1003600 EN 02 PSEN sensor technology Accessories ...

Страница 2: ...cumentation will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Internet on the Pilz homepage Pilz PIT PMI PNOZ Primo PSEN PSS PVIS SafetyBUS p SafetyEYE SafetyNET p the spirit of safety are registered and protected trademarks of Pilz GmbH Co KG in some countries SD mea...

Страница 3: ...as been made e g exchanging components on the PCB boards soldering work etc Using the documentation This document is intended for instruction Only install and commission the product if you have read and understood this document The document should be retained for future ref erence Definition of symbols Information that is particularly important is identified as follows DANGER This warning must be ...

Страница 4: ... fea tures Overview Intended use The PSEN op3 3 may only be used to implement the muting function on a safety light grid without muting sensors Use of the reflected light scanner in conjunction with the reflector as muting sensor Reflected light sensor Reflector Safety light grid The reflected light scanner emits a light beam which is reflected by the reflector This re flection is received by the ...

Страница 5: ...ment 7 Through hole for attachment 8 Rotatable connector plug block Wiring Information given in the Technical details 8 must be followed Use copper wiring with a temperature stability of 55 C The supply voltage must be provided from a power supply Use a protection class II power supply in accordance with the regulations for extra low voltages with safe separ ation a Wire the outputs from the refle...

Страница 6: ...the light grid In both positions a mounting surface must be available to which the transmitter and reflector can be attached 3 Move the transmitter and reflector horizontally and vertically until the orange LED illu minates and then goes out Attach the transmitter and reflector in the middle between these points If the muting sensors are to detect small objects the sensitivity of the receiver can ...

Страница 7: ...l to the left To detect larger objects set the control to a higher sensitivity move control to the right 2 Yellow LED Status indicator LED on Light beam is interrupted LED off Light beam is not interrupted 3 Green LED Operating status and luminosity LED on Light beam is detected device is ready for operation LED off Light beam is not detected caused by con taminations for example device is not rea...

Страница 8: ...l Approvals CE cULus Listed Electrical data Supply voltage Voltage 10 0 30 0 V Optical data Operating range 0 0 9 0 m Used wavelength range 640 nm Semiconductor outputs Switching current per output 100 mA Times Response time t1 0 50 ms Environmental data Ambient temperature Temperature range 10 55 C Storage temperature Temperature range 20 70 C Vibration In accordance with the standard EN 60068 2 ...

Страница 9: ...rews 1 50 Nm Dimensions Height 50 0 mm Width 66 0 mm Depth 18 0 mm Weight 30 g Safety characteristic data NOTICE You must comply with the safety related characteristic data in order to achieve the required safety level for your plant machine Safety characteristic data EN ISO 13849 1 2015 PL PL a Order reference Product type Features Order no PSEN op3 3 Reflex NO NC M12 Reflected light sensor with ...

Страница 10: ...T p the spirit of safety are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document depending on the status at the time of publication and the scope of the equipment We accept no responsibility for the validity accuracy and entirety of the text and graphics presented in this information Ple...