PSENop 3.3
Operating Manual PSENop 3.3
1003600-EN-02
6
Installation and setting
General
}
Torque setting: Please note the information provided under
.
If necessary, the connector plug block can be rotated by 180°.
Pull the retention spring in the direction of the con-
nector (see diagram, [1]) and rotate the connector plug
block by 180°.
[1]
Setting
INFORMATION
The sensitivity controller can be rotated by a maximum of 240°.
If the trimmer is overwound the product will be destroyed.
– Never rotate the trimmer beyond the maximum position.
1. Set the sensitivity controller on the receiver to the highest level.
2. Position the transmitter on the muting sensor and the reflector opposite each other in
parallel, in the required position in relation to the light grid. In both positions, a mounting
surface must be available, to which the transmitter and reflector can be attached.
3. Move the transmitter and reflector horizontally and vertically until the orange LED illu-
minates and then goes out. Attach the transmitter and reflector in the middle between
these points.
}
If the muting sensors are to detect small objects, the sensitivity of the receiver can be
reduced.
a
Reduce the sensitivity and determine the position in which the orange LED illumin-
ates and then goes out.
Attach transmitter
1. On the mounting surface, drill three M4 holes in the required position for the transmitter,
in accordance with the position of the through holes (see
).
2. Attach the transmitter to the mounting surface using three screws (M4, minimum length
25 mm).
Attach reflector
1. On the mounting surface, drill two M4 holes in the required position for the reflector, in
accordance with the position of the through holes.