background image

PSENop 3.3

Operating Manual PSENop 3.3
1003600-EN-02

6

Installation and setting

General

}

Torque setting: Please note the information provided under 

Technical details [

 8]

.

If necessary, the connector plug block can be rotated by 180°.

Pull the retention spring in the direction of the con-
nector (see diagram, [1]) and rotate the connector plug
block by 180°.

[1]

Setting

INFORMATION

The sensitivity controller can be rotated by a maximum of 240°.

If the trimmer is overwound the product will be destroyed.

– Never rotate the trimmer beyond the maximum position.

1. Set the sensitivity controller on the receiver to the highest level.

2. Position the transmitter on the muting sensor and the reflector opposite each other in

parallel, in the required position in relation to the light grid. In both positions, a mounting
surface must be available, to which the transmitter and reflector can be attached.

3. Move the transmitter and reflector horizontally and vertically until the orange LED illu-

minates and then goes out. Attach the transmitter and reflector in the middle between
these points.

}

If the muting sensors are to detect small objects, the sensitivity of the receiver can be
reduced.

a

Reduce the sensitivity and determine the position in which the orange LED illumin-
ates and then goes out.

Attach transmitter

1. On the mounting surface, drill three M4 holes in the required position for the transmitter,

in accordance with the position of the through holes (see 

Dimensions [

 8]

).

2. Attach the transmitter to the mounting surface using three screws (M4, minimum length

25 mm).

Attach reflector

1. On the mounting surface, drill two M4 holes in the required position for the reflector, in

accordance with the position of the through holes.

Содержание PSENop 3.3

Страница 1: ...PSENop 3 3 Operating Manual 1003600 EN 02 PSEN sensor technology Accessories ...

Страница 2: ...cumentation will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Internet on the Pilz homepage Pilz PIT PMI PNOZ Primo PSEN PSS PVIS SafetyBUS p SafetyEYE SafetyNET p the spirit of safety are registered and protected trademarks of Pilz GmbH Co KG in some countries SD mea...

Страница 3: ...as been made e g exchanging components on the PCB boards soldering work etc Using the documentation This document is intended for instruction Only install and commission the product if you have read and understood this document The document should be retained for future ref erence Definition of symbols Information that is particularly important is identified as follows DANGER This warning must be ...

Страница 4: ... fea tures Overview Intended use The PSEN op3 3 may only be used to implement the muting function on a safety light grid without muting sensors Use of the reflected light scanner in conjunction with the reflector as muting sensor Reflected light sensor Reflector Safety light grid The reflected light scanner emits a light beam which is reflected by the reflector This re flection is received by the ...

Страница 5: ...ment 7 Through hole for attachment 8 Rotatable connector plug block Wiring Information given in the Technical details 8 must be followed Use copper wiring with a temperature stability of 55 C The supply voltage must be provided from a power supply Use a protection class II power supply in accordance with the regulations for extra low voltages with safe separ ation a Wire the outputs from the refle...

Страница 6: ...the light grid In both positions a mounting surface must be available to which the transmitter and reflector can be attached 3 Move the transmitter and reflector horizontally and vertically until the orange LED illu minates and then goes out Attach the transmitter and reflector in the middle between these points If the muting sensors are to detect small objects the sensitivity of the receiver can ...

Страница 7: ...l to the left To detect larger objects set the control to a higher sensitivity move control to the right 2 Yellow LED Status indicator LED on Light beam is interrupted LED off Light beam is not interrupted 3 Green LED Operating status and luminosity LED on Light beam is detected device is ready for operation LED off Light beam is not detected caused by con taminations for example device is not rea...

Страница 8: ...l Approvals CE cULus Listed Electrical data Supply voltage Voltage 10 0 30 0 V Optical data Operating range 0 0 9 0 m Used wavelength range 640 nm Semiconductor outputs Switching current per output 100 mA Times Response time t1 0 50 ms Environmental data Ambient temperature Temperature range 10 55 C Storage temperature Temperature range 20 70 C Vibration In accordance with the standard EN 60068 2 ...

Страница 9: ...rews 1 50 Nm Dimensions Height 50 0 mm Width 66 0 mm Depth 18 0 mm Weight 30 g Safety characteristic data NOTICE You must comply with the safety related characteristic data in order to achieve the required safety level for your plant machine Safety characteristic data EN ISO 13849 1 2015 PL PL a Order reference Product type Features Order no PSEN op3 3 Reflex NO NC M12 Reflected light sensor with ...

Страница 10: ...T p the spirit of safety are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document depending on the status at the time of publication and the scope of the equipment We accept no responsibility for the validity accuracy and entirety of the text and graphics presented in this information Ple...