PSEN sl-0.5p 1.1
Operating Manual PSEN sl-0.5p 1.1
21904-EN-10
6
INFORMATION
This gives advice on applications and provides information on special fea-
tures.
Safety
Intended use
Safety function of safety switch:
}
2 safety outputs supply a high signal each when the corresponding input is high and the
actuator is in the switch's response range.
The safety gate system meets the requirements in accordance with
}
EN 60947-5-3: PDDB with the corresponding actuator PSEN sl0.5
or PSEN sl0.5fm
(see Technical details:
,
}
EN 62061: SIL CL 3
}
EN ISO 13849-1: PL e and Cat. 4
}
EN ISO 14119: Coding level Low, Type 4
}
The safety switch may only be used with the corresponding actuator (see Technical De-
The safety level PL e (Cat. 4 )/SIL CL 3 is only achieved if
}
the safety outputs use 2-channel processing.
NOTICE
Positioning of the safety switch
As the safety switch is not intended for a guard locking device for personal
protection, the safeguard monitored by the safety switch must be positioned
in a way that the access time corresponds at least to the machine's stop-
ping time.
Because of the low operating distance (see
curacy of 40 % deviates from the requirement in accordance with EN 60947-5-2 (max.
10%).
The following is deemed improper use in particular:
}
Any component, technical or electrical modification to the product
}
Use of the product outside the areas described in this manual
}
Use of the product outside the technical details (see