13
So, when installing the device close to reflective surfaces (metal walls,
floors, ceilings or workpieces), it is vital that the minimum distance in
relation to reflective surfaces is maintained, as shown in the diagram in
Fig. 9.
This minimum distance depends on:
•
The range between the transmitter
(TX)
and receiver
(RX)
•
The maximum open angle of the light beams emitted by the
transmitter, in particular:
- 10° for Type 2 ESPE (± 5° to light axis)
The values for the minimum distance in relation to the operating range
can be taken from the illustration in Fig. 9.
0
100
200
300
400
500
600
700
800
0
2
4
6
8
10
12
14
16
operating distance (m)
reflecting surface distance (mm)
Fig. 9
Type 2
ESPE