PSEN cs4.2a
Operating Manual PSEN cs4.2a
1003575-EN-08
| 30
Operation
NOTICE
The safety function should be checked after initial commissioning and each
time the plant/machine is changed. The safety functions may only be
checked by qualified personnel.
Status indicators
:
}
"Power/Fault" LED lights up green: The unit is ready for operation
}
"Safety Gate" LED lights up yellow: Actuator is within the response range
}
"Input" LED lights up yellow: There is a high signal at both inputs
Fault indicator
:
}
"Input" LED lights up yellow: the signal switches from high to low at one input, while a
high signal remains on the other input (partial operation).
Remedy: Open both channels of the input circuit.
}
"Power/Fault" LED lights up red: Error message
Remedy: Rectify fault and interrupt power supply.
Dimensions in mm
Safety switch
19
18
R
8
26,4
3
7
2
2
4
,5
Ø
8