PNOZ X7P

Operating Manual PNOZ X7P
21027-EN-05

21

Environmental data

787053

787056

787059

Vibration

In accordance with the

standard

EN 60068-2-6

EN 60068-2-6

EN 60068-2-6

Frequency

10 - 55 Hz

10 - 55 Hz

10 - 55 Hz

Amplitude

0,35 mm

0,35 mm

0,35 mm

Airgap creepage

In accordance with the

standard

EN 60947-1

EN 60947-1

EN 60947-1

Overvoltage category

III / II

III / II

III / II

Pollution degree

2

2

2

Rated insulation voltage

250 V

250 V

250 V

Rated impulse withstand

voltage

4 kV

4 kV

4 kV

Protection type

Housing

IP40

IP40

IP40

Terminals

IP20

IP20

IP20

Mounting area (e.g.

control cabinet)

IP54

IP54

IP54

Mechanical data

787053

787056

787059

Mounting position

Any

Any

Any

Mechanical life

10,000,000 cycles

10,000,000 cycles

10,000,000 cycles

Material

Bottom

PPO UL 94 V0

PPO UL 94 V0

PPO UL 94 V0

Front

ABS UL 94 V0

ABS UL 94 V0

ABS UL 94 V0

Top

PPO UL 94 V0

PPO UL 94 V0

PPO UL 94 V0

Connection type

Spring-loaded terminal Spring-loaded terminal Spring-loaded terminal

Mounting type

plug-in

plug-in

plug-in

Conductor cross section

with spring-loaded termin-

als: Flexible with/without

crimp connector

0,2 - 1,5 mm², 24 - 16

AWG

0,2 - 1,5 mm², 24 - 16

AWG

0,2 - 1,5 mm², 24 - 16

AWG

Spring-loaded terminals:

Terminal points per con-

nection

2

2

2

Stripping length with

spring-loaded terminals

8 mm

8 mm

8 mm

Dimensions

Height

101 mm

101 mm

101 mm

Width

22,5 mm

22,5 mm

22,5 mm

Depth

121 mm

121 mm

121 mm

Weight

225 g

225 g

190 g

Where standards are undated, the 2017-01 latest editions shall apply.

Содержание PNOZ X7P

Страница 1: ...PNOZ X7P Operating Manual 21027 EN 05 Safety relays...

Страница 2: ...umentation will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Interne...

Страница 3: ...Disposal 6 For your safety 6 Unit features 7 Safety features 7 Block diagram terminal configuration 7 Types AC 7 Types AC DC 8 Function Description 8 Operating modes 8 Timing diagram 9 Installation 9...

Страница 4: ...ly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive measures...

Страница 5: ...liant electrical installation The product is designed for use in an industrial environment The product may cause interference if installed in other environments If installed in other environments meas...

Страница 6: ...the generic and specialist standards applicable to the spe cific application Warranty and liability All claims to warranty and liability will be rendered invalid if The product was used contrary to th...

Страница 7: ...ty relay meets the following safety requirements The circuit is internally redundant with built in self monitoring The safety device remains effective in the case of a component failure The correct op...

Страница 8: ...ck loop Y1 Y2 is closed Input circuit is closed e g E STOP pushbutton not operated The LED CH 1 2 lights Safety contacts 13 14 and 23 24 are closed The unit is active Input circuit is opened e g E STO...

Страница 9: ...closes before start circuit b Start circuit closes before input circuit t1 Switch on delay t2 Delay on de energisation t3 Recovery time Installation The unit should be installed in a control cabinet w...

Страница 10: ...circuit Capacitance is negligible 1 phase Max cable length Imax 1 km Stub circuit Loop circuit Cable length lmax PNOZ X7P AC lmax PNOZ X7P AC WARNING If the max overall line capacitance is exceeded th...

Страница 11: ...4 1 are met Preparing for operation Supply voltage AC 24 VAC DC A1 A2 L1 N FE Input circuit Single channel Dual channel E STOP S1 A1 L L1 Safety gate S1 L L1 A1 Start circuit Automatic start Manual st...

Страница 12: ...accordance with the European Machinery Directive a check must be carried out to ensure that the safety contacts on the relay outputs open correctly Open the safety contacts switch off output and start...

Страница 13: ...respective fault has been rectified and the supply voltage is switched off for approx 1 minute the unit is ready for operation again Contact malfunctions If the contacts have welded reactivation will...

Страница 14: ...DC 1 5 W Frequency range AC 50 60 Hz 50 60 Hz 50 60 Hz Residual ripple DC 160 Duty cycle 100 100 100 Max inrush current im pulse Current pulse A1 1 7 A Pulse duration A1 8 ms Inputs 777053 777056 7770...

Страница 15: ...gory of safety contacts AC15 at 230 V 230 V 230 V Max current 4 A 4 A 5 A DC13 6 cycles min at 24 V 24 V 24 V Max current 4 A 4 A 6 A Utilisation category in ac cordance with UL Voltage 240 V AC G P 2...

Страница 16: ...th E STOP typ 70 ms 70 ms 45 ms With E STOP max 100 ms 100 ms 70 ms With power failure typ 70 ms 70 ms 45 ms With power failure max 100 ms 100 ms 70 ms Recovery time at max switching frequency 1 s Aft...

Страница 17: ...es 10 000 000 cycles 10 000 000 cycles Material Bottom PPO UL 94 V0 PPO UL 94 V0 PPO UL 94 V0 Front ABS UL 94 V0 ABS UL 94 V0 ABS UL 94 V0 Top PPO UL 94 V0 PPO UL 94 V0 PPO UL 94 V0 Connection type Sc...

Страница 18: ...r supply DC 1 5 W Frequency range AC 50 60 Hz 50 60 Hz 50 60 Hz Residual ripple DC 160 Duty cycle 100 100 100 Max inrush current im pulse Current pulse A1 1 7 A Pulse duration A1 8 ms Inputs 787053 78...

Страница 19: ...gory of safety contacts AC15 at 230 V 230 V 230 V Max current 4 A 4 A 5 A DC13 6 cycles min at 24 V 24 V 24 V Max current 4 A 4 A 6 A Utilisation category in ac cordance with UL Voltage 240 V AC G P 2...

Страница 20: ...th E STOP typ 70 ms 70 ms 45 ms With E STOP max 100 ms 100 ms 70 ms With power failure typ 70 ms 70 ms 45 ms With power failure max 100 ms 100 ms 70 ms Recovery time at max switching frequency 1 s Aft...

Страница 21: ...unting position Any Any Any Mechanical life 10 000 000 cycles 10 000 000 cycles 10 000 000 cycles Material Bottom PPO UL 94 V0 PPO UL 94 V0 PPO UL 94 V0 Front ABS UL 94 V0 ABS UL 94 V0 ABS UL 94 V0 To...

Страница 22: ...fety function s SIL PL values are not identical to the SIL PL values of the units that are used and may be different We recommend that you use the PAScal software tool to calculate the safety function...

Страница 23: ...000 cycles the PFH value see Technical details can be used in the calculation To increase the service life sufficient spark suppression must be provided on all output contacts With capacitive loads a...

Страница 24: ...eet the requirements of the directive 2006 42 EC for ma chinery of the European Parliament and of the Council The complete EC Declaration of Conformity is available on the Internet at www pilz com sup...

Страница 25: ...fetyNET p THE SPIRIT OF SAFETY are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document d...

Отзывы: