Technical details

Operating Manual PNOZ mmc4p
1002424­EN­02

19

Environmental data

772033

Airgap creepage

In accordance with the standard

EN 61131­2

Overvoltage category

II

Pollution degree

2

Rated insulation voltage

30 V

Protection type

In accordance with the standard

EN 60529

Mounting area (e.g. control cabinet)

IP54

Housing

IP20

Terminals

IP20

Potential isolation

772033

Potential isolation between

Fieldbus and module voltage

Type of potential isolation

Functional insulation

Rated surge voltage

500 V

Mechanical data

772033

Mounting position

Horizontal on top hat rail

DIN rail

Top hat rail

35 x 7,5 EN 50022

Recess width

27 mm

Material

Bottom

PC

Front

PC

Top

PC

Conductor cross section with screw terminals

1 core flexible

0,25 ­ 2,50 mm², 24 ­ 12 AWG

2 core with the same cross section, flexible with
crimp connectors, no plastic sleeve

0,20 ­ 1,50 mm², 24 ­ 16 AWG

2 core with the same cross section, flexible without
crimp connectors or with TWIN crimp connectors

0,20 ­ 1,50 mm², 24 ­ 16 AWG

Torque setting with screw terminals

0,50 Nm

Connection type

Spring­loaded terminal, screw terminal

Conductor cross section with spring­loaded terminals:
Flexible with/without crimp connector

0,20 ­ 2,50 mm², 24 ­ 12 AWG

Spring­loaded terminals: Terminal points per connec­
tion

2

Stripping length

9 mm

Dimensions

Height

100,0 mm

Width

22,5 mm

Depth

110,0 mm

Weight

95 g

The standards current on 2011­09 apply.

Содержание PNOZ mmc4p

Страница 1: ...PNOZ mmc4p Operating Manual 1002424 EN 02 Configurable Control System PNOZmulti...

Страница 2: ...KG Copies may be made for internal purposes Suggestions and comments for improving this documentation will be gratefully received Pilz PIT PMI PNOZ Primo PSEN PSS PVIS SafetyBUS p SafetyEYE SafetyNET...

Страница 3: ...2 Input and output data 10 4 3 Assigning the inputs outputs in the PNOZmulti Configurator to the DeviceNet inputs outputs 10 4 4 Block diagram 11 Section 5 Installation 12 5 1 General installation gu...

Страница 4: ...ollows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive measures that can be taken WARNING This...

Страница 5: ...Introduction Operating Manual PNOZ mmc4p 1002424 EN 02 5 INFORMATION This gives advice on applications and provides information on special fea tures...

Страница 6: ...errors 24 virtual inputs and outputs on the control system PNOZmulti can be defined in the PNOZmulti Configurator for communication with the fieldbus DeviceNet The number of inputs and outputs can be...

Страница 7: ...Overview Operating Manual PNOZ mmc4p 1002424 EN 02 7 2 3 Front view Legend 0 V 24 V Supply connections X1 DeviceNet interface 5 pin screw connector Functional earth LED Power NS MS...

Страница 8: ...STOP equipment Safety circuits in accordance with VDE 0113 Part 1 and EN 60204 1 The expansion module may not be used for safety related functions Intended use includes making the electrical installa...

Страница 9: ...k etc 3 3 3 Disposal In safety related applications please comply with the mission time tM in the safety re lated characteristic data When decommissioning please comply with local regulations regardin...

Страница 10: ...of byte 1 has the number i12 Output range The outputs are defined in the PNOZmulti Configurator Each output that is used is given a number there e g o0 o5 The status of output o0 is stored in bit 0 of...

Страница 11: ...Function description Operating Manual PNOZ mmc4p 1002424 EN 02 11 4 4 Block diagram Base unit V V CL SD CH DeviceNet 24V 0V 24V 0V...

Страница 12: ...o comply with EMC requirements the mounting rail must have a low impedance con nection to the control cabinet housing The ambient temperature of the PNOZmulti units in the control cabinet must not exc...

Страница 13: ...Installation Operating Manual PNOZ mmc4p 1002424 EN 02 13 5 3 Dimensions 115 0 4 53...

Страница 14: ...rdous voltages in the case of a fault The power supply must meet the regulations for extra low voltages with protective sep aration 6 2 Connecting the supply voltage Connect the supply voltage to the...

Страница 15: ...ff Off Off 1 Off Off Off Off Off On 2 Off Off Off Off On Off 3 Off Off Off Off On On 62 On On On On On Off 63 On On On On On On 6 6 Download modified project to the PNOZmulti safety system As soon as...

Страница 16: ...Commissioning Operating Manual PNOZ mmc4p 1002424 EN 02 16 6 7 Connection example DeviceNet Master DeviceNet Slave 1 DeviceNet Slave 2 DeviceNet Slave 3 DeviceNet Slave n PNOZ mmc4p DeviceNet...

Страница 17: ...mmc4p connects to DeviceNet and Online status is displayed on DeviceNet The MS LED flashes red 7 1 Messages Legend LED on LED flashes LED off LED Meaning NS Green PNOZ mmc4p in Link OK Online Connecte...

Страница 18: ...tor Galvanic isolation Yes Times 772033 Supply interruption before de energisation 20 ms Environmental data 772033 Ambient temperature In accordance with the standard EN 60068 2 14 Temperature range 0...

Страница 19: ...rail 35 x 7 5 EN 50022 Recess width 27 mm Material Bottom PC Front PC Top PC Conductor cross section with screw terminals 1 core flexible 0 25 2 50 mm 24 12 AWG 2 core with the same cross section flex...

Страница 20: ...r no PNOZ mm0 xp connector left Jumper yellow black to connect the modules 1 piece 779 260 Connection terminals Product type Features Order no Spring terminals PNOZ mmcxp 1 pc Spring loaded terminals...

Страница 21: ...mo PMCprotego PMCtendo PMD PMI PNOZ Primo PSEN PSS PVIS SafetyBUS p SafetyEYE SafetyNET p the spirit of safety are registered and protected trademarks of Pilz GmbH Co KG in some countries We would poi...

Отзывы: