Configurable control systems PNOZmulti 2

Содержание PNOZ m ES

Страница 1: ...PNOZ m ES Profibus Operating Manual 1002698 EN 05 Configurable control systems PNOZmulti 2...

Страница 2: ...umentation will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Interne...

Страница 3: ...unction description 11 4 1 Operation 11 4 2 Data access 11 4 3 Assigning the inputs outputs in the PNOZmulti Configurator to the PROFIBUS DP inputs outputs 12 4 4 Block diagram 12 Section 5 Installati...

Страница 4: ...Contents Operating Manual PNOZ m ES Profibus 1002698 EN 05 4 Section 8 Technical details 21 Section 9 Order reference 23 9 1 Product 23 9 2 Accessories 23...

Страница 5: ...on that is particularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates...

Страница 6: ...Introduction Operating Manual PNOZ m ES Profibus 1002698 EN 05 6 INFORMATION This gives advice on applications and provides information on special fea tures...

Страница 7: ...r PROFIBUS DP Station addresses from 0 99 selected via rotary switch Status indicators for communication with PROFIBUS DP and for errors In the PNOZmulti Configurator 128 virtual outputs of the PNOZmu...

Страница 8: ...N 05 8 2 3 Front view Legend LED Power Online Offline Fault Rotary switch x10 Tens digit for the station address x1 Units digit for the station address X1 PROFIBUS DP interface female 9 pin D Sub conn...

Страница 9: ...ts that can be connected The configurable system PNOZmulti 2 is used for the safety related interruption of safety circuits and is designed for use in Emergency stop equipment Safety circuits in accor...

Страница 10: ...y and liability All claims to warranty and liability will be rendered invalid if The product was used contrary to the purpose for which it is intended Damage can be attributed to not having followed t...

Страница 11: ...r s online help INFORMATION The GSD file is available on the Internet at www pilz de 4 2 Data access The data is structured as follows Virtual data Input area PNOZ m ES Profibus The values for the inp...

Страница 12: ...this way Input data The Master writes to the virtual inputs of the PNOZmulti 2 Description Input data from PNOZmulti 2 Virtual inputs i0 i31 4 Input Bytes Virtual inputs i32 i63 4 Input Bytes Virtual...

Страница 13: ...secured using a fixing element e g retaining bracket or end angle Open the locking slide before lifting the unit from the mounting rail To comply with EMC requirements the mounting rail must have a l...

Страница 14: ...or to the expansion module Install the expansion module in the position in which it is configured in the PNOZmulti Configurator The position of the expansion modules is defined in the PNOZmulti Config...

Страница 15: ...inal to the functional earth when the mounting rail is not connected to the functional earth Always connect the mounting rail to the protective earth via an earthing terminal This will be used to diss...

Страница 16: ...tion to PROFIBUS DP is made via a female 9 pin D Sub con nector in accordance with the guidelines of the PROFIBUS User Group PNO 1 5 9 6 1 n c 2 n c 3 B RxD TxD P 4 CNTR P 5 DGND 6 VP 7 n c 8 A RxD Tx...

Страница 17: ...in the example 1 2 3 4 9 8 7 6 0 5 x1 On the lower rotary switch x1 set the ones digit for the address 6 in the example Station address 36 is set in the diagrams as an example 6 2 2 Download modified...

Страница 18: ...ssioning Operating Manual PNOZ m ES Profibus 1002698 EN 05 18 6 2 3 Connection example PROFIBUS DP Slave 3 PROFIBUS DP Slave 1 PROFIBUS DP Master PROFIBUS DP Slave n PNOZ m ES PROFIBUS PROFIBUS DP Sla...

Страница 19: ...e PNOZ m ES Profibus does not receive a configuration from the base unit for a period of 30 s the expansion module PNOZ m ES Profibus connects to PROFIBUS DP and the ONLINE status is displayed on the...

Страница 20: ...initialisation of the PNOZ m ES Profibus does not match the configuration Remedy Ensure that the right GSD file has been used 2 Hz Configuration error length content of the configuration data during...

Страница 21: ...ission rate 9 6 kBit s 12 MBit s Connection 9 pin D Sub female connector Galvanic isolation yes Test voltage 500 V AC Environmental data Ambient temperature In accordance with the standard EN 60068 2...

Страница 22: ...onnection type Spring loaded terminal screw terminal Conductor cross section with screw terminals 1 core flexible 0 25 2 50 mm 24 12 AWG 2 core with the same cross section flexible without crimp conne...

Страница 23: ...e Features Order No PNOZ mm0 xp connector left Jumper yellow black to connect the modules 10 piece 779 260 Connection terminals Product type Features Order no Spring terminals PNOZ mmcxp 1 pc Spring l...

Страница 24: ...p the spirit of safety are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document dependin...