Pilz PNOZ m EF 8DI4DO Скачать руководство пользователя страница 22

6.2

Preparing for operation

6

Commissioning

6-2

6.2

Preparing for operation

6200

Preparing for operation

6-

6.2.1

Download modified project to the PNOZmulti safety system

Download modified project to the PNOZmulti safety system

6-

Verdrahtung_multi_Modul_Betr_geaend_Projekt_BA

As soon as an additional expansion module has been connected to the 

system, the project must be amended using the PNOZmulti Configura-

tor. Proceed as described in the operating instructions for the base unit.

6.2.2

Connection

Connection

6-

Betriebsbereitschaft herstellen

Supply voltage

Connection examples for the input circuit

NOTICE

For the commissioning and after every program change, you 

must check whether the safety devices are functioning correctly.

Supply voltage

DC

Input circuit

Single-channel

Dual-channel

Example:
E-STOP
without detection of shorts across 
contacts

Example:
E-STOP
with detection of shorts across con-
tacts

24 V

+ 24 V DC

0 V

0 V

S1

I0

L+

I0

T0

S1

S1

T1

I1

T0

I0

Содержание PNOZ m EF 8DI4DO

Страница 1: ...Operating Manual No 1002661 EN 01 Configurable Control System PNOZmulti Operating Manual PNOZ m EF 8DI4DO Operating Manual PNOZ m EF 8DI4DO PNOZ m EF 8DI4DO...

Страница 2: ...es may be made for internal purposes Suggestions and comments for improving this documentation will be gratefully received Pilz PIT PMI PNOZ Primo PSEN PSS PVIS SafetyBUS p SafetyEYE SafetyNET p the s...

Страница 3: ...rsonnel 3 2 3 2 2 Warranty and liability 3 2 3 2 3 Disposal 3 2 3 2 4 For your safety 3 3 Chapter 4 Function description 4 1 Device properties 4 1 4 1 1 Integrated protection mechanisms 4 1 4 1 2 Func...

Страница 4: ...Contents 2 Chapter 8 Technical details 8 1 Technical details 8 1 8 2 Permitted ambient temperature Tamb de pendent on the total current Isum 8 4 8 3 Order reference 8 5...

Страница 5: ...ung_alt This operating manual explains the function and operation describes the installation and provides guidelines on how to connect the product PNOZ m EF 8DI4DO Application of the product PNOZ m EF...

Страница 6: ...roduct s most important fea tures 3 Safety This chapter must be read as it contains important information on in tended use 4 Function Description This chapter describes the product s mode of operation...

Страница 7: ...rns of a hazardous situation that could lead to serious injury and death and indicates preven tive measures that can be taken CAUTION This refers to a hazard that can lead to a less serious or minor i...

Страница 8: ...1 Introduction 1 4...

Страница 9: ...and up to SIL CL 3 of EN IEC 62061 8 inputs for connecting for example E STOP pushbuttons Two hand pushbuttons Safety gate limit switches Reset buttons Light beam devices Scanners Enabling switches P...

Страница 10: ...2 2 Front view 2 Overview 2 2 2 2 Front view 2200 Front view 2 Klemmenbelegung Legende Key 0 V 24 V Supply connections Inputs I0 I7 Outputs O0 O3 LEDs POWER Run Diag Fault I Fault O Fault...

Страница 11: ...ted Bestimmung Gertebeschreibung_multi_System_2 The configurable control system PNOZmulti 2 is used for the safety re lated interruption of safety circuits and is designed for use in E STOP equipment...

Страница 12: ...y accident prevention Have read and understood the safety guidelines given in this descrip tion Have a good knowledge of the generic and specialist standards ap plicable to the specific application 3...

Страница 13: ...ic functions of the unit Information on the advanced functions can be found in the online help for the PNOZmulti Configurator and in the PNOZmulti technical cata logue Only use these functions after y...

Страница 14: ...3 Safety 3 4...

Страница 15: ...additional semi conductor outputs The function of the inputs and outputs on the control system depends on the safety circuit created using the PNOZmulti Configurator A chip card is used to download th...

Страница 16: ...4 Function description 4 2...

Страница 17: ...to heavy vibration the unit should be se cured using a fixing element e g retaining bracket or end angle Open the locking slide before lifting the unit from the mounting rail To comply with EMC requi...

Страница 18: ...5 2 Dimensions 5 Installation 5 2 5 2 Dimensions 5200 Dimensions 5 Abmessungen 22 5 0 88...

Страница 19: ...it and expansion modules 5 Montage_multi_Modul_verbind_links_mini_BA Connect the base unit and the expansion module as described in the operating instructions for the base units Connect the black yell...

Страница 20: ...5 Installation 5 4...

Страница 21: ...Commissioning Commissioning 6 6 1 General wiring guidelines 6100 General wiring guidelines 6 Verdrahtung_multi_Modul The wiring is defined in the circuit diagram of the PNOZmulti Configura tor Note In...

Страница 22: ...using the PNOZmulti Configura tor Proceed as described in the operating instructions for the base unit 6 2 2 Connection Connection 6 Betriebsbereitschaft herstellen Supply voltage Connection examples...

Страница 23: ...external power sources are excluded e g through separate multi core cables Please note that in the event of an error in the feedback loop the safety system switches to a safe condition and shuts down...

Страница 24: ...6 Commissioning 6 4...

Страница 25: ...LED on LED flashes LED off LED Fault POWER Run Diag Fault IFault OFault No supply voltage Expansion module PNOZ m EF 8DI4DO running without error Expansion module PNOZ m EF 8DI4DO is in a STOP conditi...

Страница 26: ...7 Operation 7 2...

Страница 27: ...sion 0 5 ms Maximum input delay 8 ms Semiconductor outputs Number of positive switching single pole semiconductor outputs 4 Potential isolation from system voltage yes Type of potential isolation Basi...

Страница 28: ...with screw terminals Power supply inputs configurable inputs outputs semi conductor outputs test pulse outputs 1 core flexible 0 25 2 50 mm 24 12 AWG 2 core same cross section flexible without crimp...

Страница 29: ...tegory EN IEC 62061 SIL CL PFH 1 h EN ISO 13849 1 2006 TM year Logic CPU PL e Cat 4 Cat 4 SIL CL 3 2 84E 10 20 Input SC inputs single channel PL d Cat 2 Cat 3 SIL CL 2 2 10E 09 20 SC inputs dual chann...

Страница 30: ...Tamb dependent on the total current Isum 8 Technical details 8 4 8 2 Permitted ambient temperature Tamb dependent on the total current Isum 8200 Permitted ambient temperature Tamb dependent on the to...

Страница 31: ...r reference Product type Features Order no PNOZ m EF 8DI4DO Expansion module 772 142 Order reference Accesso ries Product type Features Order no Set spring terminals 1 set of spring loaded terminals 7...

Страница 32: ...8 Technical details 8 6...

Страница 33: ...fetyEYE SafetyNET p the spirit of safety are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this...

Отзывы: