Wiring
Operating Manual PIT m4SEU
1004648-EN-02
| 49
7
Wiring
7.1
Terminal configuration
INFORMATION
The connection terminals are not supplied with the unit.
+24 V DC
0 V
Fig.: Terminal configuration
Legend
X1
MS01 ... MS05
Operating mode interface: Monitored semiconductor outputs
for the operating modes OM1 … OM5
X2
A1, A2
Terminals for connecting the supply voltage
SIo0 ... SIo3
Interface for status information: Evaluation of status informa-
tion
IDi0 ... IDi1
Key ID interface: Inputs for receiving the input signals from
the controller
The function of the terminals depends on the communication
mode that has been configured
IDo0 ... IDo3
Key ID interface: Semiconductor outputs for sending the out-
put signals to the controller
The function of the terminals depends on the communication
mode that has been configured.