PNOZ X3.1
Operating Manual PNOZ X3.1
20133-EN-06
16
Relay outputs
774321
774322
Number of output contacts
Safety contacts (N/O), instant-
aneous
3
3
Auxiliary contacts (N/C)
1
1
Max. short circuit current IK
1 kA
1 kA
Utilisation category
In accordance with the standard
EN 60947-4-1
EN 60947-4-1
Utilisation category of safety con-
tacts
AC1 at
240 V
240 V
Min. current
0,01 A
0,01 A
Max. current
8 A
8 A
Max. power
2000 VA
2000 VA
DC1 at
24 V
24 V
Min. current
0,01 A
0,01 A
Max. current
8 A
8 A
Max. power
200 W
200 W
Utilisation category of auxiliary con-
tacts
AC1 at
240 V
240 V
Min. current
0,01 A
0,01 A
Max. current
8 A
8 A
Max. power
2000 VA
2000 VA
DC1 at
24 V
24 V
Min. current
0,01 A
0,01 A
Max. current
8 A
8 A
Max. power
200 W
200 W
Utilisation category
In accordance with the standard
EN 60947-5-1
EN 60947-5-1
Utilisation category of safety con-
tacts
AC15 at
230 V
230 V
Max. current
5 A
5 A
DC13 (6 cycles/min) at
24 V
24 V
Max. current
6 A
6 A
Utilisation category of auxiliary con-
tacts
AC15 at
230 V
230 V
Max. current
5 A
5 A
DC13 (6 cycles/min) at
24 V
24 V
Max. current
6 A
6 A