PNOZ c2

Operating Manual PNOZ c2
22212-EN-04

4

Introduction

Validity of documentation

This documentation is valid for the product PNOZ c2. It is valid until new documentation is
published.
This operating manual explains the function and operation, describes the installation and
provides guidelines on how to connect the product.

Using the documentation

This document is intended for instruction. Only install and commission the product if you
have read and understood this document. The document should be retained for future ref-
erence.

Definition of symbols

Information that is particularly important is identified as follows:

DANGER!

This warning must be heeded! It warns of a hazardous situation that poses
an immediate threat of serious injury and death and indicates preventive
measures that can be taken.

WARNING!

This warning must be heeded! It warns of a hazardous situation that could
lead to serious injury and death and indicates preventive measures that can
be taken.

CAUTION!

This refers to a hazard that can lead to a less serious or minor injury plus
material damage, and also provides information on preventive measures
that can be taken.

NOTICE

This describes a situation in which the product or devices could be dam-
aged and also provides information on preventive measures that can be
taken. It also highlights areas within the text that are of particular import-
ance.

Содержание 710002

Страница 1: ...PNOZ c2 Operating Manual 22212 EN 04 Safety relays...

Страница 2: ...umentation will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Interne...

Страница 3: ...r safety 6 Unit features 7 Safety features 7 Block diagram terminal configuration 7 Function description 8 Installation 8 Wiring 8 Connect cable with crimp connector 9 Connect cable without crimp conn...

Страница 4: ...y important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive measures t...

Страница 5: ...ctrical installation The product is designed for use in an industrial environment The product may cause interference if installed in other environments If installed in other environments measures shou...

Страница 6: ...rranty and liability All claims to warranty and liability will be rendered invalid if The product was used contrary to the purpose for which it is intended Damage can be attributed to not having follo...

Страница 7: ...meets the following safety requirements The circuit is redundant with built in self monitoring The safety function remains effective in the case of a component failure The correct opening and closing...

Страница 8: ...ontacts by connecting contact expander modules or external contactors relays Installation The unit should be installed in a control cabinet with a protection type of at least IP54 Use the notch on the...

Страница 9: ...e voltage is too low increase the supply voltage until at least the lower tolerance value is reached at the inputs Connect cable with crimp connector Strip the cable 1 and apply a crimp connector Inse...

Страница 10: ...e into the terminal point 2 3 as far as it will go We recommend you use a screw driver with a 0 4 x 2 5 mm DIN 5264 blade 1 2 3 10 mm Fig Connect cable without crimp connector Disconnect cable We reco...

Страница 11: ...rt circuit proof OSSDs A1 A1 A1 A2 A2 A2 S12 S22 24 V DC GND NOTICE It must not be possible to switch off the supply voltage for the PNOZ c2 separately from the supply voltage for the safe sensor or t...

Страница 12: ...ircum stances When using the product in accordance with the European Machinery Directive it has to be checked whether the safety contacts of the relay outputs open correctly Start the device again or...

Страница 13: ...2 22212 EN 04 13 CH 2 Safety contacts of channel 2 are closed Faults malfunctions Contact malfunctions If the contacts have welded reactivation will not be possible after the input circuit has opened...

Страница 14: ...Start circuit DC 24 V Feedback loop DC 24 V Current at Input circuit DC 30 mA Start circuit DC 40 mA Feedback loop DC 40 mA Max inrush current impulse Current pulse input circuit 0 2 A Pulse duration...

Страница 15: ...U With current 4 A Pilot Duty B300 R300 External contact fuse protection safety contacts In accordance with the standard EN 60947 5 1 Max melting integral 66 A s Blow out fuse quick 4 A Blow out fuse...

Страница 16: ...60068 2 6 Frequency 10 55 Hz Amplitude 0 35 mm Airgap creepage In accordance with the standard EN 60947 1 Overvoltage category III Pollution degree 2 Rated insulation voltage 250 V Rated impulse withs...

Страница 17: ...ction must be considered when calculating the safety characteristic data INFORMATION A safety function s SIL PL values are not identical to the SIL PL values of the units that are used and may be diff...

Страница 18: ...er of cycles from which failures due to wear must be expected The wear is mainly caused by the electrical load the mechanical load is negli gible Cycles x 1000 Switching current A Fig Service life gra...

Страница 19: ...vided on all output contacts With DC contactors use flywheel diodes for spark suppression Order reference Product type Features Terminals Order No PNOZ c2 24 VDC With spring loaded terminals 710 002 E...

Отзывы: