Response and stopping times must fulfil the requirements in Maintaining the safety dis-
tance
Ensure that the safety light curtain’s response time and the machine's stopping time fulfil
the requirements in Maintaining the safety distance.
}
Check beam coding
Is beam coding displayed correctly at the receiver (see
Checking of safety light curtains
}
No intense or flashing light sources in the vicinity
There may be no especially intense or flashing light sources in the vicinity of the safety
light grid.
}
Ambient conditions
.
}
Use of deviating mirrors
Check all areas that are bounded by a deviating mirror.
Operation
Display elements
The safety light curtain’s operating status is indicated with LEDs in the end caps of the con-
nection side of the receiver and on the transmitter.
Device status
}
Reception quality:
– III: Best quality
– I: Worst quality
}
Status of the beam coding when the
protected field is interrupted
OSSD status (protected field LED)
LED indicator on the receiver