Installation
Operating Manual PSEN ml sa 1.1/2.1/2.2, PSEN ml DHM
1005457-EN-02
| 43
[2] Actuator
[3] Fixing screws of the safety switch crosswise to the respective actuator
8.3
Actuator installation
8.3.1
Important information
WARNING!
Risk of injury due to loss of the safety function.
If the actuator PSEN ml DHM is installed incorrectly, the escape release
handle may be accessible from the outside. This may mean that the guard
locking is unlocked from the outside and the safety gate is opened, although
the hazardous machine is switched on.
– The actuator should be installed so that the escape release handle is
only accessible from inside the danger zone.
}
The escape release handle must be clearly visible and must not be concealed.
}
The PSEN ml with DHM can be installed on left and right-hinged swing gates within the
protected and non-protected area.
For correct installation it's essential to comply with the distances shown in the diagram.
[1]
[2]
[3]
Legend
[1] Swing gate with installed actuators
[2] Vertical panel with installed safety switch
[3] Gate's swing radius
}
Gate's swing radius: Min. 800 mm
}
Cross section of gate profile: Max. 60 mm
}
Distance between safety switch and actuator: 5 mm + max. 1 mm
}
Installation is possible on left and right-hinged sliding gates within the protected and non-