Installation
Operating Manual PSEN ml s 1.1/2.1/2.2
1004710-EN-05
| 48
8.4.6
Rotate the bolt in the actuator housing 90°
The actuator can be installed vertically on a gate (see
). To install the actu-
ator horizontally, the bolt can be rotated 90° in the actuator housing prior to installation.
NOTICE
PSEN ml 1.1/2.1 round actuator has no anti-rotation device
Turn the bolt in the actuator housing to the correct position before installing.
1. On the housing skin [3] in the actuator housing, press down the spring plate [1] on both
sides of the bolt and keep the plate held down.
2. Rotate the bolt in the housing skin by 90° in the required direction ([2]).
[1]
[2]
[3]
Legend
[1] Spring plate in the housing skin
[2] Bolt, can be rotated 90°
[3] Housing skin
3. Centre the
bolt in the actuator housing [
.