Pilz 570 552 Скачать руководство пользователя страница 6

PSEN sl restart interlock

Operating Manual PSEN sl restart interlock
22209­EN­02

6

Safety regulations

Use of qualified personnel

The products may only be assembled, installed, programmed, commissioned, operated,
maintained and decommissioned by competent persons.

A competent person is someone who, because of their training, experience and current pro­
fessional activity, has the specialist knowledge required to test, assess and operate the
work equipment, devices, systems, plant and machinery in accordance with the general
standards and guidelines for safety technology.

It is the company’s responsibility only to employ personnel who:

}

Are familiar with the basic regulations concerning health and safety / accident preven­
tion

}

Have read and understood the information provided in this description under "Safety"

}

And have a good knowledge of the generic and specialist standards applicable to the
specific application.

Warranty and liability

All claims to warranty and liability will be rendered invalid if

}

The product was used contrary to the purpose for which it is intended

}

Damage can be attributed to not having followed the guidelines in the manual

}

Operating personnel are not suitably qualified

}

Any type of modification has been made (e.g. exchanging components on the PCB
boards, soldering work etc.).

Scope

}

1 x PSEN sl restart interlock, pre­assembled

}

2 x socket head cap screws M5x30, ISO 4762 8.8 ST zinc plated

}

2 x spring ring, DIN 127 B5 FST zinc plated

}

1 x one­way round head screw M5x30

Function description

The add­on module consists of a side section, which is fitted to the PSENslock safety
switch. A lever arm is attached to this side section. By swivelling this lever arm 90° in the
direction of the gate frame, the lever arm is positioned between the actuator and the safety
switch of the PSENslock, thereby preventing the gate from closing.

The add­on module is delivered pre­assembled and may not be modified.

Содержание 570 552

Страница 1: ...PSEN sl restart interlock Operating Manual 22209 EN 02 PSEN sensor technology...

Страница 2: ...KG Copies may be made for internal purposes Suggestions and comments for improving this documentation will be gratefully received Pilz PIT PMI PNOZ Primo PSEN PSS PVIS SafetyBUS p SafetyEYE SafetyNET...

Страница 3: ...ation 4 Using the documentation 4 Definition of symbols 4 Safety 5 Intended use 5 Safety regulations 6 Use of qualified personnel 6 Warranty and liability 6 Scope 6 Function description 6 Installation...

Страница 4: ...rmation that is particularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indi...

Страница 5: ...ation of the add on module must be prevented by means of one or two padlocks for properties see Technical details 12 The add on module may only be used with the following PSENslock products PSEN sl 0...

Страница 6: ...list standards applicable to the specific application Warranty and liability All claims to warranty and liability will be rendered invalid if The product was used contrary to the purpose for which it...

Страница 7: ...t 15 mm and may not contain any foreign bodies After installation check that the safety switch detects the safety gate as open and that the Safety Gate LED is extinguished when the add on mod ule is a...

Страница 8: ...02 8 1 2 3 4 5 6 7 Fig Installing the side section Exploded drawing Legende 1 Actuator installed on gate 2 Safety switch 3 Side section of add on module 4 Lever arm 5 Knob 6 1 x one way screw and 1 x...

Страница 9: ...njury and death Before entering the danger zone check that the guard locking device has clicked into place correctly and is secured with the padlock The add on module is now ready for use and can be a...

Страница 10: ...he lever arm and close the safety gate WARNING Loss of safety function because the add on module is defective If the add on module is damaged the safety gate can be closed unintention ally and the pla...

Страница 11: ...EN sl restart interlock Operating Manual PSEN sl restart interlock 22209 EN 02 11 Dimensions 44 2 3 4 21 Fig Dimensions in mm view from above 47 40 28 22 Fig Dimensions in mm view of lever arm from re...

Страница 12: ...luminium Lever arm Edelstahl 1 4301 Fixing screws torque settings 5 5 Nm 0 5 Nm Dimensions Height of lever arm 21 mm Lock shackle diameter min 5 mm Lock shackle diameter max 7 1 mm Lock shackle height...

Страница 13: ...these products meet the requirements of the directive 2006 42 EC for ma chinery of the European Parliament and of the Council The complete EC Declaration of Conformity is available on the Internet at...

Страница 14: ...T p the spirit of safety are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document dependi...

Отзывы: