PSEN cs6.2 M12/8
Operating Manual PSEN cs6.2 M12/8
1003425-EN-06
31
Error display
LED status
Switch status
Remedy / measure
Device
Safety Gate
Input
red
Off
Off
Internal error on
switch
Change the switch.
red
yellow
yellow
Supply voltage is
outside the toler-
ance range
Ensure the voltage supply
corresponds to the
.
yellow
Display not
definitive
Display not
definitive
Supply voltage is at
the limit of the toler-
ance range
Ensure the voltage supply
corresponds to the
.
red
Display of
last status
Display of
last status
Outputs in fault con-
dition
Check the outputs and
switch the voltage off and
then on again.
green
yellow
Display not
definitive
Wrong actuator
Use the actuator PSEN
cs6.1 M12.
Off
yellow
yellow
Switch doesn't start
Change the switch.