Pilz 542 113 Скачать руководство пользователя страница 24

PSEN cs6.11n

Operating Manual PSEN cs6.11n
1004127-EN-03

24

Times

Delay-on de-energisation

Actuator typ.

30 ms

Actuator max.

40 ms

Risk time in accordance with EN 60947-5-3

150 ms

Supply interruption before de-energisation

20 ms

Simultaneity, channel 1 and 2 max.

Environmental data

Ambient temperature

In accordance with the standard

EN 60068-2-14

Temperature range

-25 - 70 °C

Max. at max. operating height

+60 °C

Max. at max. operating height <2000 m

  +70 °C

Storage temperature

In accordance with the standard

EN 60068-2-1/-2

Temperature range

-40 - 85 °C

Climatic suitability

In accordance with the standard

EN 60068-2-30

Humidity

93 % r. h. at 40 °C

Max. operating height above sea level

4000 m

EMC

EN 60947-5-3

Vibration

In accordance with the standard

EN 60947-5-2

Frequency

10 - 55 Hz

Amplitude

1 mm

Shock stress

In accordance with the standard

EN 60947-5-2

Acceleration

30g

Duration

11 ms

Airgap creepage

Overvoltage category

III

Pollution degree

3

Rated insulation voltage

75 V

Rated impulse withstand voltage

1 kV

Protection type

Housing

IP66, IP67

Mechanical data

Magnetic holding force between actuator and sensor

30 N

Actuator 1

PSEN cs6.11 M12

Operating distances

Repetition accuracy switching distances

3 %

Change of operating distance with temperature
changes

+-0,02mm/°C

Содержание 542 113

Страница 1: ...PSEN cs6 11n Operating Manual 1004127 EN 03 PSEN sensor technology...

Страница 2: ...nta tion will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Internet...

Страница 3: ...unction description 9 Block diagram 9 Operating distances 9 Lateral and vertical offset 11 Wiring 13 Pin assignment connector and cable 13 Connection to evaluation devices 14 Single connection 14 Conn...

Страница 4: ...Contents Operating Manual PSEN cs6 11n 1004127 EN 03 4 Order reference 26 System 26 Accessories 27 EC declaration of conformity 28...

Страница 5: ...rticularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive m...

Страница 6: ...type 4 The safety switch may only be used with the corresponding actuator PSEN cs6 11 M12 The safety level PL e Cat 4 SIL CL 3 is only achieved if the safety outputs use 2 channel processing The foll...

Страница 7: ...evices systems and machines the person has to be informed of the state of the art and the applicable national European and international laws directives and standards It is the company s responsibilit...

Страница 8: ...tuators are used these must be installed as described in Installation 16 If the original actuators are replaced with substitute actuators the ori ginal actuators must be destroyed before disposal Do n...

Страница 9: ...fety output 12 Safety output 22 Signal output Y32 Yes High High High No Low Low Low Block diagram A1 A2 Power Receiver Actuator 12 22 Y32 Operating distances Alignment of the actuator Operating distan...

Страница 10: ...On Off Typical course of change in the holding force as the distance from the switch to the actuator increases with frontal approach 0 5 10 15 20 25 30 35 0 5 10 15 20 25 holding force N distance mm...

Страница 11: ...when aligning to the triangle marking Actuator aligned to the square marking on the switch 1 2 3 4 4 5 6 4 0 14 12 8 4 0 12 8 4 8 4 0 12 14 7 4 14 Legend 1 Hysteresis 2 Typical operating distance SO 3...

Страница 12: ...gle marking Actuator aligned to the square marking on the switch 4 5 7 8 1 3 2 8 4 0 12 8 4 0 12 8 4 12 16 8 4 0 12 16 16 16 6 Legend 1 Hysteresis 2 Typical operating distance SO 3 Typical release dis...

Страница 13: ...Safety relays with a wide range power supply or in AC device versions have internal potential isolation and are not suitable as evaluation devices The supply voltage to the safety switch must be prot...

Страница 14: ...0 V the safety switch may be dam aged as a result Connect the signal output Y32 to a consumer e g to the input on a control system or leave the signal output unconnected Also note the max current see...

Страница 15: ...evaluation device is described in the operating manual for the evaluation device Make sure that the connection is made in accordance with the specifications in the operating manual for the selected e...

Страница 16: ...permitted additional learning procedures is reduced by 1 NOTICE The actuator must not be removed during the learning procedure This actuator cannot be retaught on the same safety switch Installation...

Страница 17: ...ot be used as an end stop For simpler installation the mounting brackets see Order reference for Accessories 27 can be used The actuator should be protected from unauthorised removal and from contamin...

Страница 18: ...e the actuator and sensor see Dimensions in mm 21 2 Use a screw to fix the sensor to the mounting surface Make sure that the square marking on the sensor can be operated using the actuator from the ri...

Страница 19: ...the safety switch and actuator are installed facing each other in parallel Operating dis tances may deviate if other arrangements are used Note the maximum permitted lateral and vertical offset see O...

Страница 20: ...plete Switch voltage off and then on again Error display LED status Switch status Remedy measure Device Safety Gate Input red Off Off Internal error on switch Change the switch red yellow yellow Supp...

Страница 21: ...1n 1004127 EN 03 21 LED status Switch status Remedy measure Device Safety Gate Input Off yellow yellow Switch doesn t start Change the switch Dimensions in mm Safety switch 1 2 90 26 4 7 5 22 7 4 11 6...

Страница 22: ...PSEN cs6 11n Operating Manual PSEN cs6 11n 1004127 EN 03 22 Actuator 18 22 2 7 5 4 5 4 8 3 90 22 90 19 7 5 9 5 Legend 1 Square marking 2 Triangle marking 3 LEDs 4 Semicircle marking...

Страница 23: ...W Max switching frequency 3 Hz Max cable capacitance at the safety outputs No load PNOZ with relay contacts 40 nF PNOZmulti PNOZelog PSS 40 nF Max inrush current impulse Current pulse A1 0 5 A No loa...

Страница 24: ...ge 40 85 C Climatic suitability In accordance with the standard EN 60068 2 30 Humidity 93 r h at 40 C Max operating height above sea level 4000 m EMC EN 60947 5 3 Vibration In accordance with the stan...

Страница 25: ...ing screws 1 Nm Dimensions Height 26 4 mm Width 101 6 mm Depth 19 mm Actuator dimensions Height 18 mm Width 90 mm Depth 19 mm Weight of safety switch 75 g Weight of actuator 60 g Weight 135 g Where st...

Страница 26: ...ble protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and use...

Страница 27: ...st unau thorised cable disconnection or damage for safety switches PSENcode cs1 2 PSENcode cs5 6 M12 PSENslock 532 112 Cable Product type Connection 1 Connection 2 Length Order No PSS67 PDP67 cable M1...

Страница 28: ...M12 thread in stainless steel 773 614 PDP67 F 8DI ION HP VA Decentralised input module IP67 for PNOZmulti with M12 thread in stainless steel and additional supply voltage 773 615 EC declaration of co...

Страница 29: ...NET p THE SPIRIT OF SAFETY are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document depen...

Отзывы: