![Pilz 506228 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/pilz/506228/506228_operating-manual_1556396013.webp)
PSEN ma1.3n-20
Operating Manual PSEN ma1.3n-20
22176-EN-09
| 13
Defined properties of evaluation devices:
}
2-channel with feasibility monitoring
}
Open circuit monitoring of the safety switch is performed
}
Inputs and outputs on the evaluation device must fulfil the requirements of IEC 61131,
Type 3
}
Technical data of the evaluation device must fulfil the requirements in the
of PSEN ma1.3n-20/with cube
– Always comply with the max. switching current safety contacts of PSEN ma1.3n-20/
with cube.
}
Outputs at the evaluation device must only be switched on again when both reed con-
tacts at the safety switch have been opened and closed (partial operation lock)
INFORMATION
Risk time in accordance with DIN EN 60947-5-3
The risk time is made up of the reaction time of the sensor (see
) and the processing and delay times of the evaluation
device (s. operating manual for the relevant evaluation device).
PSENmag
1
4
5
2
3
Evaluation device
Input circuit
Input circuit
Fig.: Dual-channel connection PSEN ma1.3n-20/with cube to the input circuits of an evaluation
device