Pilz 506 240 Скачать руководство пользователя страница 6

PSEN ma1.3a/b-21 VA

Operating Manual PSEN ma1.3a/b-21 VA
1004515-EN-02

6

Use of qualified personnel

The products may only be assembled, installed, programmed, commissioned, operated,
maintained and decommissioned by competent persons.

A competent person is a qualified and knowledgeable person who, because of their train-
ing, experience and current professional activity, has the specialist knowledge required. To
be able to inspect, assess and operate devices, systems and machines, the person has to
be informed of the state of the art and the applicable national, European and international
laws, directives and standards.

It is the company’s responsibility only to employ personnel who

}

Are familiar with the basic regulations concerning health and safety / accident preven-
tion,

}

Have read and understood the information provided in the section entitled Safety

}

Have a good knowledge of the generic and specialist standards applicable to the spe-
cific application.

Warranty and liability

All claims to warranty and liability will be rendered invalid if

}

The product was used contrary to the purpose for which it is intended,

}

Damage can be attributed to not having followed the guidelines in the manual,

}

Operating personnel are not suitably qualified,

}

Any type of modification has been made (e.g. exchanging components on the PCB
boards, soldering work etc.).

Disposal

}

In safety-related applications, please comply with the mission time T

M

 in the safety-re-

lated characteristic data.

}

When decommissioning, please comply with local regulations regarding the disposal of
electronic devices (e.g. Electrical and Electronic Equipment Act).

For your safety

WARNING!

Loss of safety function due to manipulation of the interlocking device

Manipulation of the interlocking device may lead to serious injury and death.

– You should prevent any possibility of the interlocking device being

manipulated through the use of a spare actuator.

– Keep the substitute actuator in a safe place and protect it from unau-

thorised access.

– If spare actuators are used, these must be installed as described in

Installation [

 13]

.

– If the original actuators are replaced with substitute actuators, the ori-

ginal actuators must be destroyed before disposal.

Содержание 506 240

Страница 1: ...PSEN ma1 3a b 21 VA Operating Manual 1004515 EN 02 PSEN sensor technology...

Страница 2: ...nta tion will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Internet...

Страница 3: ...ed personnel 6 Warranty and liability 6 Disposal 6 For your safety 6 Unit features 7 Function description 7 Block diagram 7 Operating distances 8 Lateral and vertical offset 8 Wiring 9 Pin assignment...

Страница 4: ...that is particularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates pr...

Страница 5: ...e technical details see Technical details 16 NOTICE EMC compliant electrical installation The product is designed for use in an industrial environment The product may cause interference if installed i...

Страница 6: ...ty and liability will be rendered invalid if The product was used contrary to the purpose for which it is intended Damage can be attributed to not having followed the guidelines in the manual Operatin...

Страница 7: ...c Switching voltage 24 VDC LED to display switch status Switch and actuator from stainless steel Function description If the actuator is within the response range safety gate closed the safety contact...

Страница 8: ...Off Legend Sao Assured operating distance Somin Min operating distance Sar Assured release distance The offset independent values for the switching distances are included in the Technical details 16...

Страница 9: ...s cable Ensure the wiring and EMC requirements of EN 60204 1 are met Depending on which evaluation device is used the overall cable resistance must be checked before commissioning it may also be neces...

Страница 10: ...5P PNOZ X2 7P PNOZ X2 8P PNOZ X2 9P PNOZ X2C PNOZ X3 PNOZ X3 1 PNOZ X3P PNOZ X3 10P PNOZ X4 PNOZ X5 PNOZ X5J PNOZ Ex PNOZmulti for safety gate monitoring Configure the switch in the PNOZmulti Configur...

Страница 11: ...have been opened and closed partial operation lock INFORMATION Risk time in accordance with DIN EN 60947 5 3 The risk time is made up of the reaction time of the sensor see Technical details 16 and t...

Страница 12: ...sed lights No Open Off 1 2 3 4 5 6 24 V GND PSENmag 1 2 3 4 5 6 24 V PLC PSENmag Connecting the auxiliary contact to an eval uation device Connecting the auxiliary contact to a PLC Installation The un...

Страница 13: ...el Avoid the risk of damages from foreseeable external influences by attaching the safety switch and actuator If necessary safety switch and actuator have to be protected INFORMATION Protect the actua...

Страница 14: ...ght Installation of safety switch Sensing face Slide the switch through the hole in the mounting surface with the sensing face to wards the actuator Attach the switch using 2 M12x1 hexagonal nuts Also...

Страница 15: ...ate if other arrangements are used Note the maximum permitted lateral and vertical offset see Operating distances and Lateral and vertical offset 8 Periodic test Carry out a monthly function test on t...

Страница 16: ...p Ud 3 5 V 3 5 V Switching voltage 24 V 24 V Internal resistance safety contacts 10 Ohm 10 Ohm Max switching current safety con tacts 0 14 A 0 14 A Max breaking capacity safety con tacts 4 W 4 W Max s...

Страница 17: ...n operating distance Somin 0 5 mm 0 5 mm Typical operating distance So 10 mm 10 mm Assured release distance Sar 18 mm 18 mm Typical release distance Sr 13 mm 13 mm Repetition accuracy switching distan...

Страница 18: ...3 08 VA 1U Magnetic safety switch actuator with assured operating distance 8 mm Cable 5m 506 240 PSEN ma1 3b 21 PSEN ma1 3 08 VA 1U Magnetic safety switch actuator with assured operating distance 8 mm...

Страница 19: ...NET p THE SPIRIT OF SAFETY are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this document depen...

Отзывы: