T H E M O D E R M - B U S T E C H N O L O Y
12
Ve
rs
io
n E
.3
.0
1.0
0
Get started step by step
This chapter covers the different steps needed to put the PiiGAB M-Bus 900S/T gateway into
operation.
5.1
Important information
1)
Connect the PiiGAB M-Bus 900S/T to power supply and Ethernet1 as shown in table 2.1
2)
Start and wait for the Pwr led to be solid red.
3)
Read out the hardware/MAC address to be found on the right end. It has the
format E8-99-5A-XX-XX-XX
4)
Start PiiGAB M-Bus Wizard on your PC.
5)
For initial contact with the PiiGAB M-Bus 900S/T there are three possibilities depending on what
your network looks like.
a)
DHCP with router: You should be able to find your PiiGAB M-
Bus 900 directly via the Wizard’s
”Find gateways on your network”
.
b)
Direct connection: Set your computer to static IP-address 192.168.10.1 and connect it
directly to the PiiGAB M-Bus 900S/T. Turn on the power of the PiiGAB M-Bus 900S/T and wait
for about a minute. The gateway should get a random IP-address between 192.168.10.3 -
192.168.10.253. You can now use the Wizard’s ”Find gateways on your network” to find your
PiiGAB M-Bus 900S/T in the list.
c)
Static network: Turn on the power on the PiiGAB M-Bus 900 and wait for about a minute.
The unit should now receive a random IP-address within 192.168.10.3 - 192.168.10.253.
•
Start/Restart the Wizard and click on ”Change gateway
IP-
settings”, click ”Next”
•
Write the MAC-address for your PiiGAB M-
Bus 900, Click ”Next”
•
Write your preferred IP-
address, Click ”Next”, Click ”Apply”. The PiiGAB M
-Bus 900 will
now
restart. Netmask and Gateway is set by the web interface. Only the network address
will be set. Netmask will be 255.255.255.0 which means that the IP-address must be on
the same subnet as your PC.
•
The PiiGAB M-Bus Wizard will now complain that the PiiGAB M-Bus 900S/T does not
answer. Don’t worry about this instead go to ”Find gateways on your network” and make
your final settings in the web browser. All other settings are done in the web interface for
PiiGAB M-Bus 900S/T
6)
Open up a web browser and go to the PiiGAB M-Bus 900S/T
7)
Accept the PiiGAB M-Bus 900S/T security exceptions.
8)
Log onto the PiiGAB M-Bus 900S/T with default login
Username: Admin, Password: Admin
You should now be in the configuration web interface of your PiiGAB M-Bus 900S/T.
We do not recommend that any of PiiGAB’s products or products bo
ught from PiiGAB should be made
public on the internet. We always recommend that a firewall is used, not following this
recommendation will be at your own risk.