Geschäftsführer: Dr. Bernt Götz • Telefon 03641/66880 • Fax 03641/668866 • www.piezosystem.com
42
7.2.3.3. module ENV 800
power [W]
max. 104
width of the module itself
14 TE = 71mm
output voltage [V]
-20 ... 130
permanent output current [mA]
800
noise output voltage
0.3mV
RMS
@ 500 Hz
modulation input (MOD) [V]
0...10, BNC
input resistance [k
]
10
DC OFFSET
10-turn potentiometer
LC Display (shows V in open loop
configuration, µm in closed loop
configuration)
3.5 digits
display (LEDs)
green LED for Ready
red LED for Out Of Range
connector for piezo element
LEMO 0S.302
monitor output (MON) [V]
-2 ... 13, BNC (output resistance 100k
)
special features
protection circuit against voltage peaks by switching
on and off the system
over voltage protection (OOR)
overheating and short circuit protection
soft start
table 5: technical data voltage amplifier module ENV800
7.2.3.4. module ENV ** SG
You can read the common technical data in chapter ENV40, ENV300 and
ENV800. Additional technical
data’s you find in the following table.
width of the module itself
20TE = 101mm
connector for measuring system
LEMO 0S.304
display (LEDs)
green LED for CL ON
green LED for ON
red LED for Out Of Range
button „closed loop“
button for switching closed loop on or off
monitor output (MON) [V]
0...10, BNC (output resistance <1k
)
adjustment of display-ZERO
user adjustable display value for closed loop zero
position
type of feedback controller
PID
measurement system
strain gauges
time for regulation
typ. 0.01 ... 0.4 s
(depending on actuator and voltage amplifier)
table 6: technical data module ENV ** SG