MT339-I
Rev.0.3 08/04/2022
10 - 25
Document classified as: 2 - Company Confidential
5
User’s Menu
Under normal operating conditions
MODUS
keeps the display off.
To access the main menu, press the
OK
button.
You can navigate in the menu using the keys
. the keyallows you to access the submenus if
available. The key
allows you to return to the previous menu.
The menu can only be used to view quantities already configured in the equipment or to force
predefined actions. It is not possible to edit the configurations set.
The Flowmeter menu can show in the first line one or both of the following special characters listed
below
•
σ
: Metrical sealing temporary unlocked
The metrological release button was pressed. The symbol is shown as long as the display remains
lit.
•
β
:
Volume conversion stopped
Volume conversion is inhibited. The reasons can be different: pressure out of range, temperature
out of range, wrong gas parameters etc
FLOWMETER
Vb 1
Volume Counter at base conditions
–
channel 1
Vm 1
Volume Counter at measurement conditions
–
channel 1
Ve 1
Volume Counter at measurement conditions when conversion is
stopped
–
channel 1
Energy 1
Energy counter
–
channel 1
Vb2
Volume Counter at base conditions
–
channel 2
Vm 2
Volume Counter at measurement conditions
–
channel 2
Ve 2
Volume Counter at measurement conditions when conversion is
stopped
–
channel 2
Energy 2
Energy counter
–
channel 2
Measures
→
Press. 1
Absolute pressure at the measurement conditions
–
channel 1
Temp. 1
Absolute temperature at measurement conditions
–
channel 1
Zb/Z 1
Gas compression factor at the measurement conditions
–
channel 1
Zb 1
Gas compression factor at base conditions
–
channel 1
C 1
Volume conversion factor
–
channel 1
Press. 2
Absolute pressure at the measurement conditions
–
channel 2
Temp. 2
Absolute temperature at measurement conditions
–
channel 2
Zb/Z 2
Gas compression factor at the measurement conditions
–
channel 2
Zb 2
Gas compression factor at base conditions
–
channel 2
C 2
Volume conversion factor
–
channel 2
Parameters
→
Channel 1
→
Composition
See table 2
Channel 2
→
Composition
See table 2
State
→
Diagn.
See table 3
Alarms
Display of any active alarms
Residual
Battery
Percentage of residual flowmeter battery
Contat. Att.
Display of weight and pulse divider
Sistema
→
S/N Conv.
Display of the flowmeter serial number
S/N Press. 1
Display of the serial number of the pressure transducer
–
channel 1
S/N Temp. 1
Display of the serial number of the temperature transducer
–
channel 1