background image

Fault  FINDING  INstructIoNs

problem

probable cause

action

Fire difficult to start

Fire goes out

Fire burns too

quickly

smokes while 

burning

low heat output

Wood green, too damp 

or

poor quality

logs are too big

air starvation

Insufficient draught

too much draught

excessive draw

poor quality wood

Insufficient draught

Down draught

Inadequate ventilation

Incorrect fuels

-use the recommended 

fuel.

-to light the fire, use

small, very dry kindling.

to maintain the fire, use

split logs.

-open primary air

and secondary air

-check that the flue is not

obstructed, sweep it if

necessary

seek specialist advice.

-

-ensure that the primary 

air is closed. partially

close secondary air.

-Install a draught

stabiliser.

-Do not continuously

burn small wood or 

carpentry offcuts.

-check that the flue is

not obstructed, sweep if 

necessary.

Install an anti-down

draught cowl.

-Insure there is adequate

ventilation from outside

-use the recommended

fuel.

6

Содержание Glas

Страница 1: ...Gl s Non Boiler Insert Installation Operating Instructions...

Страница 2: ...ation 3 6 3 Installation Instructions 7 8 4 Operating Instruction 9 5 Exploded View Parts Listing 10 Page no STOVE DIMENSIONS Front View Left View Top View 494 mm 494 mm 596 mm 398 mm 186 mm 239 mm 31...

Страница 3: ...ion and documentation for the product is contained on this Technical data 1 Material Cast iron 2 Finish High temp Resistance paint 3 Fuel Multi Fuel 4 Log length max 30cm 6 Flue outlet Top rear 7 Flue...

Страница 4: ...ed must be fitted strictly to the manufacturer s installation instructions The flue should be checked and swept before connection to the stove There may be a need to fit a draught stabilizer if an exc...

Страница 5: ...tove by adding the extra amount to the minimum distance above the stove For example if a mantle protrudes 150mm the clearance to the mantle will increase to 600mm 550mm 50mm If the installation is int...

Страница 6: ...n until the chimney has been swept and the stove chimney and flue have been inspected by a qualified competent person IMPORTANT INFORMATION 1 This appliance should not be used as an Incinerator 2 Non...

Страница 7: ...ect fuels Use the recommended fuel To light the fire use small very dry kindling To maintain the fire use split logs Open primary air and secondary air Check that the flue is not obstructed sweep it i...

Страница 8: ...e recess in the fireplace opening to ensure a good fit Ensure the floor area is level with the hearth and there is no rocking as the insert Stove is screw fixed to the floor Step 5 If the fit of the c...

Страница 9: ...ighting the stove check 1 That all the internal parts are reassembled correctly 2 That the riddling grate primary air slider and air wash slider are working correctly 3 That the connection between the...

Страница 10: ...ng the stove riddle the fire by connecting the operating tool supplied onto the riddling control and slide the control in and out to release all the dead ash to the ashpan compartment below When addin...

Страница 11: ...A1603 Hinge Axia CA0614 16 Blanking Plate CA1102 B 17 Holder CAWK0105 18 Convection Chamber CAWK01 19 Axial Fiber CAL0103 20 Combustion Chamber CANK01 21 Handle CA0114 083 22 Fiberglass rope CA0802 23...

Страница 12: ...Unit 2 Whitemill Industrial Estate Wexford Co Wexford www piercestoves ie Email info piercestoves ie...