TROUBLESHOOTING

PROBLEM

DIAGNOSTIC

Water temperature is not hot 
enough.

1.  Press on the push buton on the top of the thermostatic handle and 

turn counterlockwise.

2.  The water heater temperature is set at 60°C (140°F).
3.  Make sure that there is no air in the water pipes.

Noise is coming from the water 
line when the shower column is 
in function.

1.  Look for air pockets in your plumbing .
2.  Look for upside-down “U” in all the pipes going to the shower, make 

sure that they are not kinked or twisted

Water temperature gets 
increasingly colder.

The problem is probably coming from your water heater, try this little test: 
Turn on the hot water faucet of the sink and see if the water is hot, if the 
water is cold the problem is coming from the water heater. the tank may 
be empty, wait 30 min and try the test again.

Cold water comes out when the 
faucet is set on hot water.

Check the two stainless steel hoses at the back of the shower column, the 
hot and cold are probably reversed.

The temperature is  hard to 
adjust when the thermostatic is 
turned.

The thermostatic cartridge probably needs to be soaked in a deliming 
solution. Please refer to the maintenance section on Page 5 of your 
owner’s manual. 

The water pressure is going 
down gradually.

1. 

Verify the filtres in the gaskets at the water entry as well as on the 

thermostatic cartridge.

2.  Look for upside-down “U” in all the pipes going to the shower, make 

sure that they are not kinked or twisted.

ATTENTION 

Any warranty will be void and ineffective in the case of a modification of the internal 

mechanism or any other component of the product. If this troubleshooting guide does not help 

you to find or fix the problem. Please call : 450-417-3740.

Содержание AQUAMASSAGE PD-890

Страница 1: ...Owner s manual PD 890...

Страница 2: ...te If the water pressure is over 5 5 bars 80 PSI you will need to install a pressure reducer to the main valve It should be set to 4 bars 58 PSI for optimum results Water consumption is less when ther...

Страница 3: ...column includes a thermostatic valve This system will maintain the water temperature in your shower even when there is other water usageinyourhome Thetemperatureoftheshowercolumnispre setat38 C 100 F...

Страница 4: ...y means of 4 nuts and bolts supplied in your assembly kit Connect the shower head water supply to the respective connector on the rough inside the column 3 We recommend to install the column at 33 83...

Страница 5: ...NTENANCE To preserve the look and finish of your shower column you should dry the shower column after each use with a dry and clean cloth Do not leave any soap residue on the surface of the shower col...

Страница 6: ...lder The problem is probably coming from your water heater try this little test Turn on the hot water faucet of the sink and see if the water is hot if the water is cold the problem is coming from the...

Страница 7: ...ordance with AQUAMASSAGE instructions or it has been modified in a manner inconsistent with product shipped by AQUAMASSAGE AQUAMASSAGE option to repair or exchange the product under this limited warra...

Страница 8: ...10f16 Inspect par Inspected by Date...

Отзывы: