PIE piecal 334 Скачать руководство пользователя страница 8

Source/Power & Measure Two Wire Transmitters

334 Ranges and Resolution

0.00 to 24.00 mA Full Span or -25.0 to 125.0% of 4-20 mA

Accuracy

EZ Check(s) at 4 & 20mA

1

0.0 to 24.00 mA

 ± (0.025% of Span at 4 mA & 20 mA)    (± 0.005mA)

 ± (0.05% of 24.00mA Span)    (± 0.012mA)

Noise

 ± ½ Least Significant Digit

Temperature effect

 ± 0.005 %/°C of FS

Loop compliance voltage

 24 DCV @ 20.00mA

Loop drive capability

1200 

 at 20 mA for 15 hours nominal; 950 

 with Hart 

Resistor enabled (334Plus)

Battery life

Source and Power measure mode 

 30 hrs at 12 mA 

nominal; 

 25 hrs with backlight on (334Plus)

1

These are internal calibrated cardinal reference points and accuracy is not defined or limited by display 

resolution

2-Wire Transmitter Simulation

Accuracy

Same as Source/Power & Measure

Voltage burden

 2V at 20 mA

Overload/Current limit protection

24 mA nominal

Loop voltage limits

2 to 100 VDC (fuse-less protected from reverse polarity 

connections)

Battery life

 125 hours nominal

Voltage Read

Range and Resolution

-99.99 to +99.99 VDC Full Span (FS)

Accuracy

 ± 0.05 % of FS

Temperature effect

 ± 100 ppm/°C of FS

Input resistance

 2 

MΩ

Battery life

 125 hours nominal

PIECAL 334 Specifications (continued)

(Unless otherwise indicated all specifications are rated from a nominal 23 °C,

70 % RH for 1 year from calibration)

Additional Information 

This product is calibrated on equipment traceable to NIST and includes a Certificate of Calibration. 

Test Data is available for an additional charge.

Practical Instrument Electronics recommends a calibration interval of one year. Contact your local 

representative for recalibration and repair services.

Shelby Jones Co

8800 W Chester Pike Upper Darby, PA 19082

610-446-6600  or Toll Free 800-346-4620 

www.Instrumentation.com

Содержание piecal 334

Страница 1: ...to check loop response and control settings The PIECAL Model 334 uses any loop power from 2 to 100V DC READ LOOP CURRENT Check controller outputs or measure the milliamp signal anywhere in the loop T...

Страница 2: ...displayed in the units selected r DIAL KNOB Turn the knob to adjust output level Turn clockwise to increase the output counter clockwise to decrease the output t EXTERNAL POWER JACK Not Shown When us...

Страница 3: ...while the EZ CHECK switch e is in the DIAL position or the current can be set at the xed points of 4 00mA 0 0 or 20 00mA 100 0 with switch e READ mA READ Percent of 4 to 20 mA Choose this function to...

Страница 4: ...IECAL Model 334 to the plus input of the device and the black source lead to the minus The PIECAL Model 334 supplies a nominal 24 volts DC at 24 mA to the 2 Wire Transmitter The current passed by the...

Страница 5: ...RCE output to full scale supplies a nominal 24V DC to power a 2 Wire Transmitter while simultaneously displaying the 4 to 20 mA output of the transmitter READ MILLIAMPS Select READ milliamps by moving...

Страница 6: ...Electronics Inc be liable for any special incidental or consequential damage SETTING UP VALVES When setting up a valve it is important to correctly set the end stops Use the PIECAL Model 334 wo supply...

Страница 7: ...dication with nominal 1 hour of operation left Protection against misconnection Over voltage protection to 135 vrms rated for 30 seconds or 240 vrms rated for 15 seconds Display High contrast backlit...

Страница 8: ...V at 20 mA Overload Current limit protection 24 mA nominal Loop voltage limits 2 to 100 VDC fuse less protected from reverse polarity connections Battery life 125 hours nominal Voltage Read Range and...

Отзывы: