![Picor PI2003-EVAL1 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/picor/pi2003-eval1/pi2003-eval1_user-manual_1555453004.webp)
Initial Test Set Up
Baseline Test Procedure
(Refer to Figure 3)
1.0 Recommended Equipment
1.1
Two Isolated DC power supplies - 0 – 60 V; 10 A
1.1.1
If the DC power supply outputs are not isolated,
two 10 A 100 V Schottky diodes are required,
as shown in Figure 4.
1.2
DC electronic load - 10 A minimum.
1.3
Digital Multimeter
1.4
Oscilloscope.
1.5
Appropriately sized interconnect cables.
1.6
Safety glasses.
1.7
PI2003 Product Data sheet.
Figure 3
– Layout configuration for a typical redundant power application, using isolated power supplies.
Figure 4 –
Layout configuration for a typical redundant power application, using non-isolated power supplies.
Picor Corporation • www.picorpower.com
PI2003-EVAL1 User Guide Rev 1.0