![PICOLAS PL-TEC-2-1024 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/picolas/pl-tec-2-1024/pl-tec-2-1024_user-manual_1555430009.webp)
9
Functional Description
The PL-TEC operating principle is based on the LDP-CW 2050. LDP-CW operates with four parallel
buck converters (S1, S2, D1, D2, L1; S3, S4, D3, D4, L2; S5, S6, D5, D6, L3; S7, S8, D7, D8, L4). Every
single converter has an independent control loop with a current sensor (Imeas1, Imeas2, Imeas3 and
Imeas4). The set point current that is pretended by the user is evenly spread over all four converters.
Several security features protect the laser diode and LDP-CW from damage. D8 protects the laser
diode from reverse currents while D7 protects the driver in case of a load failure. In case of a failure,
the control unit disables the LDP-CW. A soft-start mechanism slowly raises the current after enabling
the LDP-CW.
In contrary to the LDP-CW 2050 all 4 channels are linked to separate screw terminals. Furthermore
they are terminated with an RC-Filter to reduce the EMI noise on the TEC.
Operation Principle of LDP-CW 20 50 driver
Element
Function
S1, S2, S3, S4, S5, S6, S7, S8,
D1, D2, D3, D4, D5, D6, D7,
D8, L1, L2, L3, L4
Buck Converter
C0
Input Buffer Capacitor
D7, D8
Free wheeling and driver protection diodes