background image

PICO MACOM INC.

 

 

12500 Foothill Blvd.  •  Lakeview Terrace, CA 91342  •  (818) 897-0028  • (800) 421-6511 • FAX (818) 834-7197

I N S T A L L A T I O N

Modulator Hook-up

5

*Note:  When using the PFAD 900 in a stereo application the pre-emphasis on the M860  must be disabled.  To
disable the pre-emphasis, move SW1, slide switch, inside M860 modulator to the off position.

FUSE

FUSE

M860 Inside Top View

TO DISTRIBUTION SYSTEM

AUDIO IN

M860
Modulator

RF OUT

Rear View

VIDEO OUT

MPX OUT

PFAD 900cs
Demodulator

+

+

RF OUT

+

AUDIO IN

IF OUT

VIDEO IN

IF IN

EXT.4.5MHz IN

117VAC

60Hz 38W

600W MAX

L      GND    R

CAUTION:  FOR CONTINUED PROTECTION AGAINST FIRE
HAZARD, USE ONLY WITH SAME TYPE 0.5A  125V FUSE

M860
Modulator

TO DISTRIBUTION SYSTEM

AUDIO IN

RF OUT

Rear View

PFAD900cs
Demodulator

+

+

RF OUT

+

AUDIO IN

IF OUT

VIDEO IN

IF IN

EXT.4.5MHz IN

117VAC

60Hz 38W

600W MAX

L      GND    R

CAUTION:  FOR CONTINUED PROTECTION AGAINST FIRE
HAZARD, USE ONLY WITH SAME TYPE 0.5A  125V FUSE

CAUTION:  FOR CONTINUED PROTECTION AGAINST FIRE
HAZARD, USE ONLY WITH SAME TYPE 0.5A  125V FUSE

AUDIO OUT

VIDEO OUT

VIDEO OUT

 117VAC
60Hz 16W

RF IN

600W MAX

4.5 MHZ OUT

IF OUT

VIDEO OUT

MPX OUT

AUDIO OUT

CAUTION:  FOR CONTINUED PROTECTION AGAINST FIRE
HAZARD, USE ONLY WITH SAME TYPE 0.5A  125V FUSE

VIDEO OUT

 117VAC
60Hz 16W

RF IN

600W MAX

4.5 MHZ OUT

IF OUT

VIDEO OUT

MPX OUT

AUDIO OUT

CAUTION:  FOR CONTINUED PROTECTION AGAINST FIRE
HAZARD, USE ONLY WITH SAME TYPE 0.5A  125V FUSE

125 VAC

0.5A

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

+

NOT ALL COMPONENTS SHOWN

SW102

SW101

I.F. IN I.F. OUT

EXT.

4.5 MHz

IN

AUDIO

IN

VIDEO

IN

AURAL

LEVEL

AUDIO

MODULATION

VIDEO

MODULATION

OUTPUT

LEVEL

RF

OUT

AUDIO / VIDEO BOARD

MIXER BOARD

POWER SUPPLY BOARD

+

+

+

+

VHF OUTPUT AMP BOARD

T102

VR109

VR107

VR106

VR105

L115

VR101

VR102

VR104

VR108

RFMX-1

PRE-EMPHASIS SWITCH

VIDEO IN

SHIELD TO GND
CENTER CONDUCTOR TO L OR R

VIDEO IN

SHIELD TO GND
CENTER CONDUCTOR TO L OR R

MONAURAL APPLICATION

STEREO APPLICATION

RF IN

RF IN

FUSE

125 VAC

0.5A

FUSE

125 VAC

0.5A

FUSE

125 VAC

0.5A

FUSE

Содержание PFAD900CS

Страница 1: ...0 Foothill Blvd Lakeview Terrace CA 91342 818 897 0028 800 421 6511 FAX 818 834 7197 FREQUENCY AGILE AUDIO AND VIDEO DEMODULATOR Doc No OM2143N 2 REV B ECO 1770 P N 911045 Installation And Operation Manual PFAD 900cs NTSC ...

Страница 2: ...ning Unplug this appliance from the wall outlet before cleaning Use a damp cloth for cleaning Do not use liquid cleaners or aerosol cleansers 6 Do Not Use Attachments not recommended by the manufac turer or they may cause hazards Important Information 7 Water and Moisture Do not use this product near water for example near a bathtub washbowl kitchen sink laundry tub in a wet basement or near a swi...

Страница 3: ...ly from the type of power source indicated on the marking label If you are not sure of the type of power supplied to your home consult your appliance dealer or local power company 12 Power cord Protection Power supply cords should be routed so they are not likely to be walked on or pinched by items placed upon or against them Pay particular attention to cords and plugs convenience receptacles and ...

Страница 4: ...vision signal in the 54 MHz to 806 MHz frequency range and converts it to baseband video and audio Two additional outputs are provided by the PFAD 900cs an I F output to monitor the status of the tuner and also for use with other up converters and a composite multiplex output is provided for stereo applications PICO MACOM INC backs the product with a two year limited warranty Specifications RF Ban...

Страница 5: ... used 1 Power on LED Indicates power is on when lit 2 Channel Number Display Indicates demodulated channel 3 Mode LED s Indicates which mode is operative TV Standard CATV CATV IRC or CATV HRC 4 Mode Selector Switch Push this button to select mode 5 Channel Down Switch Push this button to select lower channel 6 Channel Up Switch Push this button to select higher channel 7 RF In This F connector acc...

Страница 6: ...AINST FIRE HAZARD USE ONLY WITH SAME TYPE 0 5A 125V FUSE CAUTION FOR CONTINUED PROTECTION AGAINST FIRE HAZARD USE ONLY WITH SAME TYPE 0 5A 125V FUSE AUDIO OUT VIDEO OUT VIDEO OUT 117VAC 60Hz 16W RF IN 600W MAX 4 5 MHZ OUT IF OUT VIDEO OUT MPX OUT AUDIO OUT CAUTION FOR CONTINUED PROTECTION AGAINST FIRE HAZARD USE ONLY WITH SAME TYPE 0 5A 125V FUSE VIDEO OUT 117VAC 60Hz 16W RF IN 600W MAX 4 5 MHZ OU...

Страница 7: ...he PHC 12U twelve channel passive com biner consists of two rows of directional cou plers combined by a hybrid splitter The direc tional coupler combining provides high isola tion 40 dB between the inputs Normally the odd channels are combined on one row while even channelsarecombinedon theotherrow of directional couplers The combiner loss is 16 dB per channel Ch 2 Ch 3 Ch 4 36dBmV 60dBmV SP600 BS...

Страница 8: ...will be issued a Return Authoriza tion RA number which will be used to track your product Be prepared to provide 1 The model number and channel number of the product 2 The date of purchase 3 A specific identification of the problem Delivertheproductsto PicoMacom Inc or ship the products in the origi nal packing material at the address at the bottom of the page Include satisfactory evidence of the ...

Страница 9: ...PICO MACOM INC 12500 Foothill Blvd Lakeview Terrace CA 91342 818 897 0028 800 421 6511 FAX 818 834 7197 N O T E S ...

Страница 10: ...PICO MACOM INC 12500 Foothill Blvd Lakeview Terrace CA 91342 818 897 0028 800 421 6511 FAX 818 834 7197 N O T E S ...

Страница 11: ...PICO MACOM INC 12500 Foothill Blvd Lakeview Terrace CA 91342 818 897 0028 800 421 6511 FAX 818 834 7197 N O T E S ...

Страница 12: ...PICO MACOM INC 12500 Foothill Blvd Lakeview Terrace CA 91342 818 897 0028 800 421 6511 FAX 818 834 7197 PICO MACOM INC U S A Spec Tru ...

Отзывы: