MPC12

3

Rev. 06/03

Ph: 800-421-6511

www.picomacom.com

Safeguards

11. Power Sources: 

This product should be operated only from the

type of power source indicated on the marking label. If you are not
sure of the type of power supplied to your home, consult your appli-
ance dealer or local power company.

12. Power-cord Protection:

Power-supply cords should be routed

so they are not likely to be walked on or pinched by items placed upon
or against them. Pay particular attention to cords and plugs, conven-
ience receptacles, and the point where they exit from the appliance.

13. Lightning:

For added protection for this product during a lightning

storm, or when it is left unattended or unused for long periods of time,
the unit should be disconnected from power source.

14. Power Lines:

An outside antenna system should not be located

in the vicinity of overhead power lines, other electric light or power cir-
cuits, where it can fall into such power lines or circuits. When installing
an outside antenna system, extreme care should be taken to keep
from touching such power lines or circuits as contact with them may
be fatal.

15. Overloading:

Do not overload wall outlets and extension cords as

this can result in risk of fire or electric shock.

16. Object and Liquid Entry:

Never push objects of any kind into this

product through openings as they may touch dangerous voltage
points or short-out parts that could result in a fire or electric shock.
Never spill liquid of any kind on the product.

17. Servicing:

Do not attempt to service this product yourself as

opening or removing covers may expose you to dangerous voltage or
other hazards. Refer all servicing to qualified service personnel.

18. Damage Requiring Service:

Unplug this product from the wall

outlet and refer servicing to qualified service personnel under the fol-
lowing conditions:

a.

When the power-supply cord or plug is damaged.

b.

If liquid has been spilled, or objects have fallen into the product.

c.

If the product has been exposed to rain or water.

d.

If the product does not operate normally by following the oper-

ating instruction. Adjust only those controls that are covered by
the operating instructions. An improper adjustment may result in
damage and will often require extensive work by a qualified tech-
nician to restore the product to its normal operation.

e.

If the product has been dropped or the cabinet has been

damaged.

f.

When the product exhibits a distinct change in performance—

this indicates a need for service.

19. Replacement Parts: 

When replacement parts are required, be

sure the service technician has used replacement parts specified by
the manufacturer or have the same characteristics as the original
parts. Unauthorized substitutes may result in fire, electric shock or
other hazards.

20. Safety Check:

Upon completion of any service or repairs to this

product, ask the service technician to perform safety checks to deter-
mine that the product is in proper operating conditions.

21. Outdoor Antenna Grounding:

Before attempting to install this

product, be sure the antenna or cable system is grounded so as to

provide some protection against voltage surges and built-up static
charges.

a.

Use No.10 AWG (5.3mm) copper, No.8 AWG (8.4mm) alu-

minum, No.7 AWG (10mm) copper-clad steel or bronze wire or
larger, as  ground wire.

b.

Secure antenna lead-in and ground wires to house with stand-

off insulators spaced from 4 feet (1.22m) to 6 feet (1.83m) apart.

c.

Mount antenna discharge unit as close as possible to where

lead-in enters house.

d.

A driven rod may be used as the grounding electrode where

other types of electrode systems do not exist. Refer to the
National Electrical Code, ANSI/NFPA 70-1984 for information.

e.

Use jumper wire not smaller than No.6 AWG (13.3mm) copper

or equivalent, when a separate antenna grounding electrode is
used.

 

 

  

NOTE TO THE CATV SYSTEM INSTALLER

THIS REMINDER IS PROVIDED TO CALL THE CATV SYSTEM
INSTALLER’S ATTENTION TO ARTICLE 820-22 OF THE NEC
THAT PROVIDES GUIDELINES FOR PROPER GROUNDING
AND, IN PARTICULAR, SPECIFIES THAT THE CABLE
GROUND SHALL BE CONNECTED TO THE GROUNDING
SYSTEM OF THE BUILDING, AS CLOSE TO THE POINT OF
CABLE ENTRY AS PRACTICAL.

Содержание MPC12

Страница 1: ...Installation and Operation Manual MPC12 12 Slot Universal Mini Mod Chassis and Power Supply Operation Manual Rev 06 03 Ph 800 421 6511 www picomacom com ...

Страница 2: ...er for example near a bathtub washbowl kitchen sink laundry tub in a wet basement or near a swimming pool and the like 8 Accessories Do not place this product on an unstable cart stand tripod bracket or table The product may fall causing serious injury to a child or adult and serious damage to the appliance 9 Ventilation This video product should never be placed near or over a radiator or heat reg...

Страница 3: ...as been exposed to rain or water d If the product does not operate normally by following the oper ating instruction Adjust only those controls that are covered by the operating instructions An improper adjustment may result in damage and will often require extensive work by a qualified tech nician to restore the product to its normal operation e If the product has been dropped or the cabinet has b...

Страница 4: ...upply 4 module wide is a 70 Watt capacity module specifically designed for mini modulator applications requiring a highly reliable DC input supply Sophisticated packaging and filtering techniques are used to minimize the need for overall system filtering The MPC12 power supply employs high effi ciency current overload technology and a whisper quiet cooling fan to reduce heat transfer within the ch...

Страница 5: ...rating Temperature 0 to 60 C Storage Temperature 40 to 85 C Overcurrent Protection No damage to outputs when shorted to ground Power Supply MPC12 12 Mini Mod Chassis and Power Supply MPC PSF Power Supply Module with Wire Harness for MPC12 MPC12C Universal Chassis chassis only MPC BP Blank Cover Plate Ordering Information Connectors Input on back plane IEC 320 inlet connector Dimensions 19 L x 71 2...

Страница 6: ... run configuration allows removal of modules without disabling entire system Back Panel 1 3 1 Top slide guide This channel accepts the top edge of equipment modules 2 Power LED This LED will illuminate when proper AC voltage is provided to power sup ply module 3 MPC PSF 12 16 Power Supply Switching power supply provides 12Vdc and 5 Vdc to the equip ment modules MPC PSF 12 16 power supply input wil...

Страница 7: ...2 at the desired elevation in rack 2 Line up the mounting holes of chassis with the tapped equipment rack holes 3 Insert the provided screws through the mounting holes at the extreme left and right of faceplate and thread into the tapped equip ment rack holes 4 Fasten the bottom screws first then fasten top screws tighten securely 5 Insert equipment modules into chassis by aligning the top and bot...

Страница 8: ... return merchandise authorization RMA number for the failed equipment and ask for a loaner unit We will issue an invoice for the List Price of the loaner unit plus shipping costs When you receive the loaner unit pack the failed unit in the loaner unit s box and ship it freight prepaid to Pico Macom for repair When you receive the repaired unit a new RMA number will be provided in the box Carefully...

Отзывы: