Страница 1: ...Installation and Operation Manual MPC12 12 Slot Universal Mini Mod Chassis and Power Supply Operation Manual Rev 06 03 Ph 800 421 6511 www picomacom com ...

Страница 2: ...er for example near a bathtub washbowl kitchen sink laundry tub in a wet basement or near a swimming pool and the like 8 Accessories Do not place this product on an unstable cart stand tripod bracket or table The product may fall causing serious injury to a child or adult and serious damage to the appliance 9 Ventilation This video product should never be placed near or over a radiator or heat reg...

Страница 3: ...as been exposed to rain or water d If the product does not operate normally by following the oper ating instruction Adjust only those controls that are covered by the operating instructions An improper adjustment may result in damage and will often require extensive work by a qualified tech nician to restore the product to its normal operation e If the product has been dropped or the cabinet has b...

Страница 4: ...upply 4 module wide is a 70 Watt capacity module specifically designed for mini modulator applications requiring a highly reliable DC input supply Sophisticated packaging and filtering techniques are used to minimize the need for overall system filtering The MPC12 power supply employs high effi ciency current overload technology and a whisper quiet cooling fan to reduce heat transfer within the ch...

Страница 5: ...rating Temperature 0 to 60 C Storage Temperature 40 to 85 C Overcurrent Protection No damage to outputs when shorted to ground Power Supply MPC12 12 Mini Mod Chassis and Power Supply MPC PSF Power Supply Module with Wire Harness for MPC12 MPC12C Universal Chassis chassis only MPC BP Blank Cover Plate Ordering Information Connectors Input on back plane IEC 320 inlet connector Dimensions 19 L x 71 2...

Страница 6: ... run configuration allows removal of modules without disabling entire system Back Panel 1 3 1 Top slide guide This channel accepts the top edge of equipment modules 2 Power LED This LED will illuminate when proper AC voltage is provided to power sup ply module 3 MPC PSF 12 16 Power Supply Switching power supply provides 12Vdc and 5 Vdc to the equip ment modules MPC PSF 12 16 power supply input wil...

Страница 7: ...2 at the desired elevation in rack 2 Line up the mounting holes of chassis with the tapped equipment rack holes 3 Insert the provided screws through the mounting holes at the extreme left and right of faceplate and thread into the tapped equip ment rack holes 4 Fasten the bottom screws first then fasten top screws tighten securely 5 Insert equipment modules into chassis by aligning the top and bot...

Страница 8: ... return merchandise authorization RMA number for the failed equipment and ask for a loaner unit We will issue an invoice for the List Price of the loaner unit plus shipping costs When you receive the loaner unit pack the failed unit in the loaner unit s box and ship it freight prepaid to Pico Macom for repair When you receive the repaired unit a new RMA number will be provided in the box Carefully...