background image

Page 7.5

ULTRA HIGH DENSITY MATRIX MODULE  40-535/536/537

pickering

SECTION 7 - MAINTENANCE INFORMATION

TABLE 7.3 - Dual44x4 Ultra High Density Matrix 40-536-021  Relay Numbering - 

Motherboard

Matrix 

Crosspoint Relay 

No.

Matrix 

Crosspoint Relay 

No.

Matrix 

Crosspoint Relay 

No.

Matrix 

Crosspoint Relay 

No.

X

Y

X

Y

X

Y

X

Y

101

101

1

101

102

47

101

103

93

101

104

139

102

101

2

102

102

48

102

103

94

102

104

140

103

101

3

103

102

49

103

103

95

103

104

141

104

101

4

104

102

50

104

103

96

104

104

142

105

101

5

105

102

51

105

103

97

105

104

143

106

101

6

106

102

52

106

103

98

106

104

144

107

101

7

107

102

53

107

103

99

107

104

145

108

101

8

108

102

54

108

103

100

108

104

146

109

101

9

109

102

55

109

103

101

109

104

147

110

101

10

110

102

56

110

103

102

110

104

148

111

101

11

111

102

57

111

103

103

111

104

149

112

101

12

112

102

58

112

103

104

112

104

150

113

101

13

113

102

59

113

103

105

113

104

151

114

101

14

114

102

60

114

103

106

114

104

152

115

101

15

115

102

61

115

103

107

115

104

153

116

101

16

116

102

62

116

103

108

116

104

154

117

101

17

117

102

63

117

103

109

117

104

155

118

101

18

118

102

64

118

103

110

118

104

156

119

101

19

119

102

65

119

103

111

119

104

157

120

101

20

120

102

66

120

103

112

120

104

158

121

101

21

121

102

67

121

103

113

121

104

159

122

101

22

122

102

68

122

103

114

122

104

160

123

101

23

123

102

69

123

103

115

123

104

161

124

101

24

124

102

70

124

103

116

124

104

162

125

101

25

125

102

71

125

103

117

125

104

163

126

101

26

126

102

72

126

103

118

126

104

164

127

101

27

127

102

73

127

103

119

127

104

165

128

101

28

128

102

74

128

103

120

128

104

166

129

101

29

129

102

75

129

103

121

129

104

167

130

101

30

130

102

76

130

103

122

130

104

168

131

101

31

131

102

77

131

103

123

131

104

169

132

101

32

132

102

78

132

103

124

132

104

170

133

101

33

133

102

79

133

103

125

133

104

171

134

101

34

134

102

80

134

103

126

134

104

172

135

101

35

135

102

81

135

103

127

135

104

173

136

101

36

136

102

82

136

103

128

136

104

174

137

101

37

137

102

83

137

103

129

137

104

175

138

101

38

138

102

84

138

103

130

138

104

176

139

101

39

139

102

85

139

103

131

139

104

177

140

101

40

140

102

86

140

103

132

140

104

178

141

101

41

141

102

87

141

103

133

141

104

179

142

101

42

142

102

88

142

103

134

142

104

180

143

101

43

143

102

89

143

103

135

143

104

181

144

101

44

144

102

90

144

103

136

144

104

182

45

91

137

183

46

92

138

184

Содержание PXI 40-535

Страница 1: ...s underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos...

Страница 2: ...pickeringtest com Issue 5 1 February 2020 40 535 536 537 User Manual PXI Ultra High Density Matrix Module...

Страница 3: ...020 PICKERING INTERFACES ALL RIGHTS RESERVED No part of this publication may be reproduced transmitted transcribed translated or stored in any form or by any means without the written permission of Pi...

Страница 4: ...r to ISO 14001 Pickering Interfaces strives to fulfil all relevant environmental laws and regulations and reduce wastes and releases to the environment Pickering Interfaces aims to design and operate...

Страница 5: ...dicate hazards arising from dangerous voltages WARNING CAUTION An appropriate safety instruction should be followed or caution to a potential hazard exists Refer to the relevant instructions detailed...

Страница 6: ...1 Functional Description 2 1 Section 3 Installation 3 1 Pre Operation Checks 3 1 Hardware Installation 3 2 Software Installation 3 2 Testing Operation 3 3 Section 4 Programming Guide 4 1 Programming...

Страница 7: ...Page VI ULTRA HIGH DENSITY MATRIX MODULE 40 535 536 537 pickering THIS PAGE INTENTIONALLY BLANK...

Страница 8: ...h The host chassis must be correctly installed and be connected to mains or factory safety ground please refer to your chassis installation manual Diagram Showing Separation Between The Mains Circuit...

Страница 9: ...nt to be isolated and disconnected from the power source and user I O signals refer to the Maintenance Section Appropriate manual handling procedures should be followed as dictated by the weight of th...

Страница 10: ...01 X103 X105 X106 X107 X109 X110 X111 Y102 Y104 Y101 Y103 Y202 Y204 Y201 Y203 X202 X204 X208 X201 X203 X205 X206 X207 X209 X210 X211 X144 X142 X143 X244 X242 X243 M A T R I X C R O S S P O I N T X2 X4...

Страница 11: ...PXI CompactPCI Compliance The module is compliant with the PXI Specification 2 2 Local Bus Trigger Bus and Star Trigger are not implemented Uses a 33MHz 32 bit backplane interface Safety CE Complianc...

Страница 12: ...ur local Pickering sales office Mating Connectors Cabling For connection accessories for the 40 535 536 537 modules please refer to the 90 016D 96 pin micro D Connector Accessories data sheet where a...

Страница 13: ...specification Legacy and Hybrid Peripheral slots in a 3U PXI Express PXIe chassis Pickering Interfaces LXI or LXI USB Modular Chassis Chassis Selection Guide Standard PXI or hybrid PXIe Chassis from...

Страница 14: ...ase go to pickeringtest com software Signal Routing Software Our signal routing software Switch Path Manager automatically selects and energizes switch paths through Pickering switching systems Signal...

Страница 15: ...Page 1 6 ULTRA HIGH DENSITY MATRIX MODULE 40 535 536 537 pickering SECTION 1 TECHNICAL SPECIFICATION THIS PAGE INTENTIONALLY BLANK...

Страница 16: ...nergised via control signals from relay drivers The relay drivers are addressed by PCI bridge U1 to output the required signal Module configuration is determined by hardwired links and data stored in...

Страница 17: ...Page 2 2 ULTRA HIGH DENSITY MATRIX MODULE 40 535 536 537 pickering SECTION 2 TECHNICAL DESCRIPTION THIS PAGE INTENTIONALLY BLANK...

Страница 18: ...ssis relative to any other equipment the module s will connect with Ensure the chassis is not connected to the electrical supply 3 Ensure that the designated area for the chassis containing the module...

Страница 19: ...d refer to page VII Ensure that there is adequate ventilation The module should be installed in accordance with the following procedure 1 Ensure that the system is turned OFF but still connected to ma...

Страница 20: ...t Front Panel GSFP using the desktop icon or via the Start menu Start Menu Pickering Interfaces Ltd General Soft Front Panel A selector panel will appear listing all installed Pickering PCI PXI or LXI...

Страница 21: ...Page 3 4 ULTRA HIGH DENSITY MATRIX MODULE 40 535 536 537 pickering SECTION 3 INSTALLATION THIS PAGE INTENTIONALLY BLANK...

Страница 22: ...ormation on the installation and use of drivers and the programming of Pickering s products in various software environments please refer to the Software User Manual This is available as a download fr...

Страница 23: ...36 and 40 537 are controlled in the same way but are a dual 16x8 matrix and a single 44x8 matrix respectively In the case of single matrices the entire matrix is treated as a single programming sub un...

Страница 24: ...nit and close with pipx40_close Setting a Matrix Crosspoint Using the IVI driver Note the following example is for bank 1 of a dual matrix Bank 1 is identified as A bank 2 would be identified as B and...

Страница 25: ...Page 4 4 ULTRA HIGH DENSITY MATRIX MODULE 40 535 536 537 pickering SECTION 4 PROGRAMMING GUIDE THIS PAGE INTENTIONALLY BLANK...

Страница 26: ...79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 X1 X3 X5 X7 X9 X11 X13 X15 X17 X19 X21 X23 X25 X27 X29 X31 X33 X35 X37 X39 X41 X43 X45 X47 X49 X51 X53 X55 X57 X59 X61 X63 X65 X67 X69 X71 X73 X75...

Страница 27: ...07 X109 X111 X113 X115 X117 X119 X121 X123 X125 X127 X129 X131 X133 X135 X137 X139 X141 X143 Y102 Y104 X201 X203 X205 X207 X209 X211 X213 X215 X217 X219 X221 X223 X225 X227 X229 X231 X233 X235 X237 X2...

Страница 28: ...8 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31...

Страница 29: ...Page 5 4 ULTRA HIGH DENSITY MATRIX MODULE 40 535 536 537 pickering SECTION 5 CONNECTOR INFORMATION THIS PAGE INTENTIONALLY BLANK...

Страница 30: ...f the system s PCI configuration highlighting any potential configuration problems Specific details of all installed Pickering switch cards are included All the installed Pickering switch cards should...

Страница 31: ...ULTRA HIGH DENSITY MATRIX MODULE 40 535 536 537 Page 6 2 pickering SECTION 6 TROUBLE SHOOTING THIS PAGE INTENTIONALLY BLANK...

Страница 32: ...s a simple process which is described in the manual for the Modular LXI Chassis SWITCHING SYSTEM TEST TOOLS We recommend the use of eBIRST to provide a check of the correct operation of relays and to...

Страница 33: ...2 65 19 3 111 19 4 157 20 1 20 20 2 66 20 3 112 20 4 158 21 1 21 21 2 67 21 3 113 21 4 159 22 1 22 22 2 68 22 3 114 22 4 160 23 1 23 23 2 69 23 3 115 23 4 161 24 1 24 24 2 70 24 3 116 24 4 162 25 1 2...

Страница 34: ...2 4 154 63 1 17 63 2 63 63 3 109 63 4 155 64 1 18 64 2 64 64 3 110 64 4 156 65 1 19 65 2 65 65 3 111 65 4 157 66 1 20 66 2 66 66 3 112 66 4 158 67 1 21 67 2 67 67 3 113 67 4 159 68 1 22 68 2 68 68 3 1...

Страница 35: ...U27 C37 U28 C38 U9 C19 C8 C9 C18 C17 U6 U5 R3 U7 C16 R2 C7 C6 C42 C5 U29 C39 U10 C20 U30 C40 U11 C21 U31 C41 U12 C22 U17 C27 U13 C23 U18 C28 U14 C24 U19 C29 U15 C25 U20 C30 U16 C26 R1 U2 or U8 U3 C15...

Страница 36: ...55 118 101 18 118 102 64 118 103 110 118 104 156 119 101 19 119 102 65 119 103 111 119 104 157 120 101 20 120 102 66 120 103 112 120 104 158 121 101 21 121 102 67 121 103 113 121 104 159 122 101 22 12...

Страница 37: ...202 65 217 203 111 217 204 157 218 201 20 218 202 66 218 203 112 218 204 158 219 201 21 219 202 67 219 203 113 219 204 159 220 201 22 220 202 68 220 203 114 220 204 160 221 201 23 221 202 69 221 203...

Страница 38: ...U27 C37 U28 C38 U9 C19 C8 C9 C18 C17 U6 U5 R3 U7 C16 R2 C7 C6 C42 C5 U29 C39 U10 C20 U30 C40 U11 C21 U31 C41 U12 C22 U17 C27 U13 C23 U18 C28 U14 C24 U19 C29 U15 C25 U20 C30 U16 C26 R1 U2 or U8 U3 C15...

Страница 39: ...112 20 8 160 3 1 17 9 1 65 15 1 113 21 1 161 3 2 18 9 2 66 15 2 114 21 2 162 3 3 19 9 3 67 15 3 115 21 3 163 3 4 20 9 4 68 15 4 116 21 4 164 3 5 21 9 5 69 15 5 117 21 5 165 3 6 22 9 6 70 15 6 118 21 6...

Страница 40: ...87 243 26 4 20 33 4 76 40 4 132 188 244 26 5 21 33 5 77 40 5 133 189 245 26 6 22 33 6 78 40 6 134 190 246 26 7 23 33 7 79 40 7 135 191 247 26 8 24 33 8 80 40 8 136 192 248 27 1 25 34 1 81 41 1 137 193...

Страница 41: ...C103 U107 C102 U106 C101 U105 U104 U103 U102 U101 C109 C110 C108 RL256 RL255 RL254 RL253 RL252 RL251 RL250 RL249 RL248 RL247 RL246 RL245 RL244 RL243 RL242 RL241 RL240 RL239 RL238 RL237 RL236 RL235 RL...

Страница 42: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Отзывы: