Page 1.3
PXI/PXIe 2-POLE HIGH DENSITY MATRIX (40/42-588)
pickering
SECTION 1 - TECHNICAL SPECIFICATION
2-Pole High Density Matrices, 40/42-588
pickering
test
.com
Specifications
Operating/Storage Conditions
Operating Conditions
Operating Temperature:
Humidity:
Altitude:
0 °C to +55 °C
Up to 90 % non-condensing
5000 m
Storage and Transport Conditions
Storage Temperature:
Humidity:
Altitude:
-20 °C to +75 °C
Up to 90 % non-condensing
15000 m
PXI & CompactPCI Compliance - 40-588
The module is compliant with the PXI Specification
2.2. Local Bus, Trigger Bus and Star Trigger are not
implemented.
Uses a 33 MHz 32-bit backplane interface.
PXIe Compliance - 42-588
The module is compliant with the PXIe Specification
1.0. Local Bus, Trigger Bus and Star Trigger are not
implemented.
Safety & CE Compliance
All modules are fully CE compliant and meet
applicable EU directives: Low-voltage safety EN61010-
1:2010, EMC Immunity EN61326-1:2013, Emissions
EN55011:2009+A1:2010.
Maximum Crosspoint Count
The 40/42-588 has a suggested maximum number of
simultaneously operated crosspoints of 50 (please contact
factory for applications requiring higher closure counts).
Mechanical Characteristics
40-588 - Two slot 3U PXI (CompactPCI card).
42-588 - Two slot 3U PXIe, compatible with PXIe hybrid slot.
3D models for these modules in a variety of popular file
formats are available on request.
Module weight: 720 g
Connectors
40-588 - PXI bus via 32-bit P1/J1 backplane connector.
42-588 - PXIe bus via XJ3 and XJ4 backplane connectors.
Signals via front panel mounted connectors:
• 40/42-588-222 - Two 104-pin male D-types.
• 40/42-588-212 - One 104-pin male D-type.
For pin outs please refer to the operating manual.
Architecture diagram for the 40/42-588 showing how the two 16x8 daughter cards are interconnected with the
analog bus to create a 32x8 matrix (all signal paths and crosspoints are 2-pole).
X Connections
Analog Bus
Y Connections
Isolation
Switches
X Connections
16x8 Matrix
16x8 Matrix
8
Isolation
Switches