Page 1.2
PXI/PXIe 2-POLE HIGH DENSITY MATRIX (40/42-588)
pickering
SECTION 1 - TECHNICAL SPECIFICATION
2-Pole High Density Matrices, 40/42-588
pickering
test
.com
Specifications
Power Requirements - 40-588
+3.3 V
+5 V
+12 V
-12 V
150 mA
750 mA (max) 0
0
Power Requirements - 42-588
+3.3 V
+12 V
TBD
TBD
Switching Specifications
Switch Type:
Electro-mechanical
Contact Type:
Palladium-Ruthenium,
Gold Covered Bifurcated
Max Switch Voltage:
220V DC/250 VAC*
Max Power:
Max Switch Current:
Max Continuous Carry Current:
Max Pulsed Carry Current
Example
(for a single switch path):
62.5 VA, 60 W
2.0 A
2.0 A
6 A for 100 ms
(up to 10 % duty cycle)
Initial Path Resistance
On (Single Module):
Off (Single Module):
Minimum Voltage:
Differential Thermal Offset:
<450 mΩ (X-Y connection)
>10
9
Ω
100 μV
<10 μV
Operate Times
Crosspoint Relay:
Crosspoint & Isolation Relay:
<3 ms
<6 ms
Expected Life (operations)
Very low power signal load:
Low power load (2W):
Medium power load (30W):
Full power load (60W):
>1x10
8
>1.5x10
7
(0.1 A 20V DC)
>5x10
6
(1 A 30V DC)
>1x10
5
(2 A 30V DC)
* For full voltage rating, signal sources to be switched must
be fully isolated from mains supply and safety earth.
RF Specification
Bandwidth (-3dB):
35 MHz to 70 MHz (depending
upon path selected)
VSWR (typical):
<1.5:1 to 85 MHz
Crosstalk (typical):
10k Hz:
100 kHz:
1 MHz:
10 MHz:
25 MHz:
50 MHz:
-65 dB
-65 dB
-45 dB
-25 dB
-25 dB
-25 dB
Isolation (typical):
10 kHz:
100 kHz:
1 MHz:
10 MHz:
25 MHz:
50 MHz:
65 dB
65 dB
65 dB
50 dB
30 dB
30 dB
40-588-222 Typical Insertion Loss Plot
40-588-222 Typical VSWR Plot