STOVE STATUS
Function
Action
Display
Select stove status
menu
Press the MENU key, then using the SELECT MENU key select the stove
status “STATE STOVE” menu.
Confirm by pressing the SET key.
S T A T E
S T O V E
P U L
0 2 . 4 C O
0 9 5
2 6
.c
.c
1
1
Display stove status
The first line displays the operating conditions, the second line for how
long the pellets have been loading and the third line the smoke and room
temperatures detected by the sensors. A list of the readouts which appears
on the display:
PUL
Clean grate
ALF 1
Pressure switch activated
ALF 2
Pressure switch fault
ALC
Safety thermostat activated
NO CONN
Smoke sensor disconnected
NO ACC
Failed ignition
MASS TEMP
Smoke alarm activated - maximum temperature reached
MAX VENT
Room fan at maximum
00. 0CO
Auger fault.
S T A T E
S T O V E
P U L
0 2 . 4 C O
0 9 5
2 6
.c
.c
1
1
DT2040071-05
ENABLE BEEP (audio signal)
Function
Action
Display
Select enable beep
menu
Press the MENU key. Using the SELECT MENU key select the “
ENABLE
BEEP
” menu and confirm by pressing the SET key.
E N A B L E
B E E P
M O D E
B E E P
O N
1
1
Select enable or
disable beep
Press the SELECT MENU key and select "
ON
" to enable the buzzer or
"
OFF
" to disable it. Confirm by pressing the SET key. After confirmation the
readout "
BUZZER ENABLES
" will appear on the display while the initial
display will automatically reappear on the remote control.
E N A B L E
B E E P
M O D E
B E E P
O N
1
1
DT2040065-03
DT2040065-03
6.14 ENAbLE bEEP (AUdIO SIGNAL)
DT2012057-00
6.15 STOvE STATUS
This function allows you to engage or disengage the alarm signal emitted by the stove to indicate that it has received the remote control’s commands.
This function displays the stove status under the various operating conditions.
H07026300 / DT2000786 – 00