PI P-725.1CDE2 Скачать руководство пользователя страница 38

User Manual 

P725T0010, applies to P-725 

CBo/KSch, 8/27/2020 
 

 

Physik Instrumente (PI ) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany 

Page 38 / 40 

Phone +49 721 4846-0, Fax +49 721 4846-1019, Email 

[email protected]

, 

www.pi.ws

 

Pin Assignment 

P-725.xCL, P-725.x0L 

 

 

 

 

Fig. 14: 

LEMO connector for the P-725.xCL (above) and P-725.x0L (below) 
1

 

LEMO coaxial connector for capacitive sensor (Probe) 

2

 

LEMO coaxial connector for capacitive sensor (Target) 

3

 

LEMO coaxial connector for piezo voltage 

 

LEMO coaxial connectors 

 

Fig. 15: 

LEMO coaxial connectors 

Connector  Signal 

Function 

Connector shell 

Probe 

Probe sensor signal (immovable part 

of the capacitive sensor) 

Cable shield 

Target 

Target sensor signal (movable part 

of the capacitive sensor) 

Cable shield 

PZT 

PZT 

Piezo voltage 

Piezo voltage ground on cable 

shield 

 

Содержание P-725.1CDE2

Страница 1: ...uf der Roemerstrasse 1 76228 Karlsruhe Germany Phone 49 721 4846 0 Fax 49 721 4846 1019 Email info pi de www pi ws P 725 P 725 PIFOC Long Travel Objective Scanner P 725 1CDE2 PIFOC Piezo Nanofocusing...

Страница 2: ...er Cable with D sub Mechanics to LEMO Electronics 12 Adapter Cable with LEMO Mechanics to D sub Electronics 13 Unpacking 13 Installation 13 Connecting the P 725 to the Protective Earth Conductor 13 Mo...

Страница 3: ...846 0 Fax 49 721 4846 1019 Email info pi de www pi ws Customer Service Department 30 Technical Data 31 Specifications 31 Maximum Ratings 33 Ambient Conditions and Classifications 33 Dimensions 34 Torq...

Страница 4: ...of control technology drive technologies and suitable safety measures is assumed Typographic Conventions Symbol Label Meaning 1 2 Action consisting of several steps with strict sequential order Actio...

Страница 5: ...e from the actual circumstances Photographic illustrations may also differ and are not binding Other Applicable Documents Product Document P 5xx P 6xx P 7xx piezo positioning systems PZ240 Short Instr...

Страница 6: ...cope of delivery of the P 725 The P 725 may only be started operated maintained and cleaned by authorized and qualified staff Safety Precautions CAUTION Dangerous voltage and residual charge in piezo...

Страница 7: ...h conductor has to be removed temporarily e g for modification reconnect the P 725 to the protective earth conductor before restarting NOTICE Falling down when removing the thread adapters The P 725 c...

Страница 8: ...0 m capacitive sensors LEMO connectors for QuickLock adapters P 725 4CL PIFOC piezo nanofocusing system for long travel ranges 400 m capacitive sensors LEMO connectors for QuickLock adapters P 725 1CA...

Страница 9: ...el Product Labeling Labeling Description P 725 2CD Product name example the characters after the period refer to the model 123456789 Serial number example individual for each P 725 Meaning of each pos...

Страница 10: ...r Connector P 725 xCD P 725 1CDE2 P 725 xCA P 725 CDD Capacitive sensor D sub E 621 controller module E 625 servo controller benchtop device E 665 servo controller with digital interface benchtop devi...

Страница 11: ...pter set M26 1 36 for objective and microscope P 721 08Q QuickLock thread adapter set M19 0 75 for objective and microscope P 721 11Q QuickLock thread adapter set M25 0 75 for objective and microscope...

Страница 12: ...pe W0 8 1 36 P 725 13M Thread adapter for microscope SM1 1 035 40 P 725 14M Thread adapter for microscope M34 1 P 725 xxL thread adapter Product no Description Suitability P 725 models P 725 02L Threa...

Страница 13: ...y according to the contract and the delivery note 3 If any parts are damaged or missing contact our customer service department immediately p 30 4 Keep all packaging materials in case the product need...

Страница 14: ...arth conductor to the protective earth connector of the P 725 as shown in the profile view 3 Tighten the M4 screw with a torque of 1 2 Nm to 1 5 Nm 4 Make sure that the contact resistance at all point...

Страница 15: ...t Overview Fig 3 P 721 xxQ thread adapter with PIFOC positioner and microscope objective 1 Thread adapter microscope side 1a Thread for microscope 1b Clamping ring 2 PIFOC positioner 3 Tightening tool...

Страница 16: ...f the thread adapter set 1 Narrow side of the key tool 2 Wide side of the key tool Mounting the P 721 xxQ thread adapter set NOTICE Possible damage due to excessive torque Only moderate torque is requ...

Страница 17: ...washer on the microscope side is neither too tight nor loose If necessary set the tension of the spring washer by turning the clamping ring Only unscrew the clamping ring as far as necessary 6 Push t...

Страница 18: ...e www pi ws P 721 xxA Thread Adapter Set for P 721 xxA and P 725 xCA The P 721 xxA QuickLock thread adapters with large apertures are available with various different inner diameters QuickLock thread...

Страница 19: ...et s scope of delivery 3 PIFOC positioner 4 Key tool included in the thread adapter set s scope of delivery 4a Narrow side of the key tool 4b Wide side of the key tool 5 Thread adapter objective side...

Страница 20: ...et p 11 Hex key supplied see Fig 6 p 19 Key tool supplied see Fig 6 p 19 Mounting the P 721 xxA thread adapter set 1 Screw the thread adapter for the objective side into the aperture of the PIFOC posi...

Страница 21: ...Insert the PIFOC positioner into the thread adapter screwed on the microscope 7 Tighten the thread adapter on the microscope side in the PIFOC positioner using the hex key supplied as shown in the fol...

Страница 22: ...Aperture diameter P 725 02M P 725 02L M26 0 75 22 P 725 03M P 725 03L M27 0 75 22 P 725 04M P 725 04L M28 0 75 22 P 725 05M P 725 05L M32 0 75 25 P 725 06M P 725 06L M26 1 36 22 P 725 08M P 725 08L M...

Страница 23: ...P 725 xxM thread adapter Mounting the P 725 xxM and P 725 xxL thread adapters 1 Insert the thread adapter for the objective side into the aperture of the PIFOC positioner from below 2 Use the Torx wr...

Страница 24: ...INFORMATION Note that only the thread adapter on the objective side is required when mounting the P 725 using the mounting holes in the base body The following figures serve as examples and can diffe...

Страница 25: ...8 P 725 xxL thread adapter Clamp the thread adapter in the aperture of the P 725 For details refer to P 725 xxM and P 725 xxL Thread Adapters for P 725 1CDE2 p 22 2 Optional Align the P 725 to the mic...

Страница 26: ...on reconnect the P 725 to the protective earth conductor before restarting NOTICE Destruction of the piezo actuator due to electric flashovers The use of the P 725 in environments that increase the el...

Страница 27: ...itioner without ID chip The positioner s ID chip does not contain any calibration data Connecting the positioner via LEMO connectors no ID chip lines If the positioning accuracy is reduced after repla...

Страница 28: ...e P 725 is accidentally pulled out of the electronics during operation Requirements You have read and understood the safety precautions p 6 Discharging a P 725 Connected to the Electronics In closed l...

Страница 29: ...onics before cleaning Prevent cleaning fluid from penetrating the housing of the P 725 NOTICE Damage from ultrasonic cleaning Ultrasonic cleaning can damage the P 725 Do not do any ultrasonic cleaning...

Страница 30: ...Screw the objective out before removing Hold the P 725 firmly when you loosen the upper thread adapter To demount the objective and the PIFOC positioner reverse the steps as described in Installation...

Страница 31: ...ed 680 470 330 230 as P 725 xCL Hz 20 Resonant frequency under load 150 g 290 185 140 120 as P 725 xCL Hz 20 Push pull force capacity in positioning direction 100 20 100 20 100 20 100 20 as P 725 xCL...

Страница 32: ...20 Resonant frequency unloaded 1180 1180 Hz 20 Resonant frequency under load 200 g 450 450 Hz 20 Push pull force capacity in positioning direction 100 20 100 20 N Max Drive properties Ceramic type PI...

Страница 33: ...he mechanical resonant frequency 2 The heat that is generated by the piezo actuator during dynamic operation limits the value for maximum power consumption Details can be found at the following websit...

Страница 34: ...Co KG Auf der Roemerstrasse 1 76228 Karlsruhe Germany Page 34 40 Phone 49 721 4846 0 Fax 49 721 4846 1019 Email info pi de www pi ws Dimensions Note that the decimal places are separated by a comma i...

Страница 35: ...8 27 2020 Physik Instrumente PI GmbH Co KG Auf der Roemerstrasse 1 76228 Karlsruhe Germany Page 35 40 Phone 49 721 4846 0 Fax 49 721 4846 1019 Email info pi de www pi ws Fig 11 P 725 xCD xCL Dimension...

Страница 36: ...h 8 27 2020 Physik Instrumente PI GmbH Co KG Auf der Roemerstrasse 1 76228 Karlsruhe Germany Page 36 40 Phone 49 721 4846 0 Fax 49 721 4846 1019 Email info pi de www pi ws Fig 12 P 725 xCA dimensions...

Страница 37: ...40 Phone 49 721 4846 0 Fax 49 721 4846 1019 Email info pi de www pi ws Fig 13 P 725 xDD dimensions in mm please order the adapter set separately Torque for Stainless Steel Screws A2 70 Screw size Mini...

Страница 38: ...above and P 725 x0L below 1 LEMO coaxial connector for capacitive sensor Probe 2 LEMO coaxial connector for capacitive sensor Target 3 LEMO coaxial connector for piezo voltage LEMO coaxial connectors...

Страница 39: ...i ws P 725 SDD Fig 16 LEMO connectors for the P 725 SDD 1 LEMO connector 4 pole for the strain gauge sensor 2 LEMO coaxial connector for piezo voltage Sensor connector Fig 17 LEMO connector 4 pole for...

Страница 40: ...voltage 4 Not connected 5 Input Target sensor signal movable part of the capacitive sensor The connector shell is connected to the cable shield Old Equipment Disposal In accordance with EU law electri...

Отзывы: