5 Installation
18
Version: 1.0.0
PZ248E
P-56x Nanopositioners
NOTICE
Mechanical overload from incorrect handling!
An impermissible mechanical overload of the moving platform of the P-56x can
cause damage to the piezo actuators, sensors and flexure joints of the P-56x as well
as losses of accuracy.
Only hold the P-56x externally by the base body.
NOTICE
Damage from unsuitable cables!
Unsuitable cables can damage the stage and the electronics.
Only use cables provided by PI for connecting the P-56x to the electronics.
NOTICE
Damage from incorrect mounting!
Incorrect mounting of the P-56x or incorrectly mounted parts can damage the P-56x.
Only mount the P-56x and the loads on the mounting fixtures (holes) intended for
this purpose.
NOTICE
Damage due to incorrectly tightened screws!
Incorrectly tightened screws can cause damage.
Observe the torque range (p. 43) given for the screws used during installation.
INFORMATION
Extended cables can reduce the positioning accuracy of the P-56x or affect the
sensor processing by the electronics.
Do
not
use cable extensions. If you need longer cables, contact our customer
service department (p. 37).