7 Maintenance
M-238 High-Load Linear Actuator
MP77E
Version: 1.1.0
17
NOTICE
Damage due to improper maintenance!
The M-238 can become misaligned by incorrect maintenance.
Loosen screws only according to the instructions in this manual or the instructions of our
customer service department (p. 21).
7.1
Lubricating the M-238
Depending on the operating conditions and the period of use of the M-238, the following
maintenance measures are required:
Maintenance Run
The maintenance run serves the purpose of distributing the existing lubricant.
If the M-238 is moved continuously over a short travel range (<20 % of the entire travel
range) in an industrial situation, do a run across the entire travel range approximately
every 2000 motion cycles.
Relubricating
Under laboratory conditions, the positioner needs relubrication in exceptional cases only. For
continuous industrial use, the lubrication intervals must be determined individually.
If you have any questions on relubricating, contact our customer service department
(p. 21).
7.2
Cleaning the M-238
Requirements
You have disconnected the linear actuator from the controller.
Cleaning the Linear Actuator
Do
not
use any organic solvents.
If necessary, clean the surfaces of the linear actuator using a cloth dampened with a
mild cleanser or disinfectant.
7
Maintenance