10 Technical Data
M228 / M229 Linear Actuators
MP86E
Version: 2.0.0
37
10.1.3
Ambient Conditions and Classifications
Pay attention to the following ambient conditions and classifications for the M-228 / M-229:
Area of application
For indoor use only
Maximum altitude
2000 m
Relative humidity
Highest relative humidity 80 % for temperatures up to 31 °C
Decreasing linearly to 50 % relative air humidity at 40 °C
Storage temperature
0 °C to 80 °C
Transport temperature
0 °C to 80 °C
Supply fluctuations
Not more than ±10 % of the nominal voltage
Overvoltage category
II
Protection class
I
Degree of pollution
2
Degree of protection
according to IEC 60529
IP40
10.1.4
Limit Switch Specifications
Type
Magnetic (Hall effect) sensor
Supply voltage
+5 V / ground
Signal output
TTL level
Signal logic
The signal level changes when passing the limit switch. The signal
logic is active low. That means:
Normal motor operation: high (+5 V)
Limit switch reached: low (0 V)
10.1.5
Reference Switch Specifications
Type
Magnetic (Hall effect) sensor
Supply voltage
+5 V/GND
Signal output
TTL level
Signal logic
Index pulse when passing the reference switch.