phyCORE Development Board PCM-982
PHYTEC Messtechnik GmbH 2005 L-645e_1
67
10.3.5
Second CAN Interface at Plug P1B
Plug P1B is the top plug of the double DB-9 connector at P1. P1B is
connected to the second CAN interface (CAN_1) of the
phyCORE-MCF548x via jumpers. Depending on the configuration of
the CAN transceivers and their power supply, the following two
configurations are possible:
1.
CAN transceiver populating the phyCORE-MCF548x is populated
and the CAN signals from the module extend directly to plug P1B.
Jumper
Setting
Description
JP3
1 + 2
Pin 7 of the DB-9 plug P1B is connected to CAN_H1
from on-board transceiver on the phyCORE module
JP4
1 + 2
Pin 2 of the DB-9 plug P1B is connected to CAN_L1
from on-board transceiver on the phyCORE module
Table 16:
Jumper Configuration for CAN Plug P2B Using the CAN
Transceiver on the phyCORE-MCF548x
1
2
3
4
7
6
5
8
9
Pin 7 CAN_H1 (non-isolated)
Pin 2 CAN_L1 (non-isolated)
Pin 6 CAN_GND
Pin 3 CAN_GND
Figure 19:
Pin Assignment of the DB-9 Plug P1B (CAN Transceiver on
phyCORE-MCF548x, Front View)
Содержание phyCORE-MCF548x
Страница 1: ...A product of a PHYTEC Technology Holding company phyCORE MCF548x Hardware Manual Edition January 2005 ...
Страница 8: ...phyCORE MCF548x PHYTEC Messtechnik GmbH 2005 L 645e_1 ...
Страница 30: ...phyCORE MCF548x 22 PHYTEC Messtechnik GmbH 2005 L 645e_1 ...
Страница 40: ...phyCORE MCF548x 32 PHYTEC Messtechnik GmbH 2005 L 645e_1 ...
Страница 44: ...phyCORE MCF548x 36 PHYTEC Messtechnik GmbH 2005 L 645e_1 ...
Страница 104: ...Published by PHYTEC Messtechnik GmbH 2005 Ordering No L 645e_1 Printed in Germany ...