phyCORE-LPC2292/94
38
©
PHYTEC Messtechnik GmbH 2006 L-658e_5
The following configurations are possible:
First CAN Interface
J602
J604
CAN_H1 at X700D21
CAN_L1 at X700D20
open*
1
CAN1_Rx at X700D21
CAN1_Tx at X700D20
closed
closed
2
Second CAN Interface
J603
J604
CAN_H2 at X700C18
CAN_L2 at X700D18
open*
1
open*
1
CAN2_Rx at X700C18
CAN2_Tx at X700D18
closed
2
closed
2
* = Default setting
Table 23:
J602, J603, J604 and J605 CAN Interface Configuration
3.15
J606 Write Protection of SPI EEPROM
Various types of SPI EEPROM devices can populate space U607.
Some of these devices provide a write protection function
. Closing
Jumper J606 connects pin 3 of the serial EEPROM with GND and
thus activates write protection.
The following configurations are possible:
Write Protection EEPROM
J606
Write protection of EEPROM deactivated
open*
Write protection of EEPROM activated
closed
* = Default setting
Table 24:
J606 EEPROM Write Protection
1
: Should only be used if CAN transceivers U605 and U606 are populated.
2
:
Note!
Should only be used if CAN transceivers U605 and U606 are
NOT
populated.
3
:
Refer to the corresponding EEPROM Data Sheet for more information on the write
protection function
.
Содержание phyCORE-LPC2292/94
Страница 1: ...A product of a PHYTEC Technology Holding company phyCORE LPC2292 94 Hardware Manual Edition July 2006...
Страница 12: ...phyCORE LPC2292 94 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Страница 76: ...phyCORE LPC2292 94 64 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Страница 80: ...phyCORE LPC2292 94 68 PHYTEC Messtechnik GmbH 2006 L 658e_5...
Страница 88: ...phyCORE LPC2292 94 76 PHYTEC Me technik GmbH 2006 L 658e_5...
Страница 132: ...phyCORE LPC2292 94 120 PHYTEC Me technik GmbH 2006 L 658e_5...
Страница 136: ...phyCORE LPC2292 94 124 PHYTEC Me technik GmbH 2006 L 658e_5...
Страница 142: ...phyCORE LPC2292 94 130 PHYTEC Me technik GmbH 2006 L 658e_5...
Страница 144: ...Published by PHYTEC Me technik GmbH 2006 Ordering No L 658e_5 Printed in Germany...