The phyCORE-i.MX on the Carrier Board
©
PHYTEC Messtechnik GmbH 2011 L-710e_5
75
Table 28: Audio/Touchscreen interface jumper settings
1
J
UMPER
S
ETTING
D
ESCRIPTION
JP21
2 + 3
1 + 2
x_MC1RIN is connected to X11
MIC1 is connected to X11
JP22
2 + 3
1 + 2
x_MC1LIN is connected to X11
MIC2 is connected to X11
JP19
2 + 3
1 + 2
x_RXOUTL is connected to X12
LINE_INR is connected to X12
JP20
2 + 3
1 + 2
x_RXOUTR is connected to X12
LINE_INL is connected to X12
JP23
2 + 3
1 + 2
x_RXINL is connected to X13
LINE_OUTR is connected to X13
JP24
2 + 3
1 + 2
x_RXINR is connected to X13
LINE_OUTL is connected to X13
JP25
2 + 3
1 + 2
x_TSY1 is connected to X23
TP_Y- is connected to X23
JP26
2 + 3
1 + 2
x_TSX2 is connected to X23
TP_X+ is connected to X23
JP27
2 + 3
1 + 2
x_TSY2 is connected to X23
TP_Y+ is connected to X23
JP28
2 + 3
1 + 2
X_TSX1 is connected to X23
TP_X- is connected to X23
JP47
open
closed
Reset is held high, no asserting by GPIO of i.MX module
Reset can be asserted by GPIO of i.MX module
JP48
open
closed
No access to IRQ via GPIO of i.MX module
Access to IRQ via GPIO of i.MX module
JP49
open
closed
No access to PENDOWN via GPIO of i.MX module
Access to PENDOWN via GPIO of i.MX module
Caution!
Jumper JP47 to JP49 always have to be opened with the phyCORE-i.MX27. Functions behind this
jumpers are not available for the i.MX27 module.
1
Settings for the phyCORE-i.MX27 audio/touchscreen interface are in
bold blue
Содержание phyCORE-i.MX27
Страница 1: ...A product of a PHYTEC Technology Holding company phyCORE i MX27 HARDWARE MANUAL EDITION FEBRUARY 2011 ...
Страница 34: ...phyCOREi MX27 26 PHYTEC Messtechnik GmbH 2011 L 710e_5 ...
Страница 38: ...phyCOREi MX27 30 PHYTEC Messtechnik GmbH 2011 L 710e_5 ...
Страница 52: ...phyCOREi MX27 44 PHYTEC Messtechnik GmbH 2011 L 710e_5 ...
Страница 56: ...phyCOREi MX27 48 PHYTEC Messtechnik GmbH 2011 L 710e_5 ...
Страница 60: ...phyCOREi MX27 52 PHYTEC Messtechnik GmbH 2011 L 710e_5 X2 X2 X2 Figure 15 phyMAP i MX27 bottom view ...
Страница 94: ...phyCOREi MX27 86 PHYTEC Messtechnik GmbH 2011 L 710e_5 ...
Страница 100: ...Published by PHYTEC Messtechnik GmbH 2011 Ordering No L 710e_5 Printed in Germany ...