Table 26: CF interface jumper settings
1
J
UMPER
S
ETTING
D
ESCRIPTION
JP4
closed
open
/PC_RW signal can manage the data direction of U13
Data direction of U13 is from controller to CF
JP5
closed
open
Compact Flash is Master
Compact Flash is Slave
JP17
open
closed
Output 2 of U15 is active
Output 2 of U15 is disabled
JP602
closed
open
PC_RW non-inverted
PC_RW inverted
JP604
closed
open
Power supply of CF is forced active
Power supply of CF can be managed by GPIO signal x_EXP007