pciGrabber-4x4
144
PHYTEC Messtechnik GmbH 2008 L-720e_0
Has another channel been selected after switching over to
S-Video with Set_Channel?
For S-video operation the image is only black/white
Is the chroma-signal properly applied?
Is the Grabber configured to S-video operation?
For S-video operation the image is black/white with color distur-
bances.
Is the chroma-signal properly connected?
Is a S-video-source connected (not a composite)?
The image is displayed incompletely/ or very slowly
Increase the delaytime between status inquiries. The PCI-bus
might be blocked by too many calls concerning the status.
Was the resolution reduction concerning to time used?
The image has no contrast / too bright / too dark
Check the setting of brightness, contrast etc.
If necessary activate the AGC
The image skips or the fields are mismatched
The time delay during switching the channels was too short.
The image appears without color / with the wrong format
Is the appropriate color system selected?
Was the Grabber correctly initialized?
Was the delaytime after channel switching long enough?
Содержание pciGrabber4x4
Страница 1: ...A product of a PHYTEC Technology Holding company Grabber 4x4 Hardware Manual Edition January 2009...
Страница 8: ...pciGrabber 4x4 PHYTEC Messtechnik GmbH 2008 L 720e_0...
Страница 10: ...pciGrabber 4x4 2 PHYTEC Messtechnik GmbH 2008 L 720e_0...
Страница 44: ...pciGrabber 4x4 36 PHYTEC Messtechnik GmbH 2008 L 720e_0...
Страница 73: ...Programming Manual PHYTEC Messtechnik GmbH 2008 L 720e_0 65 Programming Manual Part 2 Programming Manual...
Страница 103: ...Programming Manual PHYTEC Messtechnik GmbH 2008 L 720e_0 95 Programming Manual 0 nDevNo Max_Device_Number are accepted...
Страница 128: ...pciGrabber 4x4 120 PHYTEC Messtechnik GmbH 2008 L 720e_0 Figure 49 Color Format of the pciGrabber 4x4...
Страница 159: ...Index PHYTEC Messtechnik GmbH 2008 L 720e_0 151...