22
Operating Switch
Timer Functions:
The control switch can be used to automatically turn the heater on then off at desired preset times.
First - Set current clock time (24 hour clock)
Second - Set the desired start time
Third - Set the desired stop time
Important Note:
Once the Automatic Start Time or Automatic Stop Time are set, the operating switch will retain these
settings and the timer function will remain activated. It will continue to operate as set on a repeating
daily basis until both the Automatic Start Time and Automatic Stop Time are both set to “00:00”
PHP Gen II Air Heater Control Switch - Operation Instructions
Timer Functions:
The control switch can be used to automatically turn the heater on then off at desired preset times.
First Set current clock time (24 hour clock)
Second Set the desired start time.
Third Set the desired stop time.
Important Note:
Once the Automatic Start Time or Automatic Stop Time are set, the operating switch will
retain these settings and the timer function will remain activated. It will continue to operate
as set on a repeating daily basis until both the Automatic Start Time and Automatic Stop
Time are both se
Set Clock Time (Heater must of off):
Press and Hold for 3 seconds.
Set the clock time.
When the
double colon
flashes you can set the clock
time.
1) Rotate to set the 10s of hours
2) Press to move to 1s of hours.
3) Rotate to set the 1s of hours.
4) Press to move to 10s of minutes
5) Rotate to set 10s of minutes
6) Press to set 1s of minutes
7) Rotate to set 1s of minutes
Press to proceed to setting Automatic Start Time.
Colon
appears
Flashing
Clock with Flashing Hours
(1
st
digit from Left)
Clock with Flashing Hours
(2
nd
digit from Left)
Clock with Flashing Minutes
(3rd digit from Left)
Clock with Flashing Minutes
(4
th
digit from Left)