D69-P06-01 GB R6
01/07/2020
www.photowatt.com
22
PW72HT-C
Use two insertion profiles running parallel to the
long side frame.
Maximum Load :
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa
Use two insertion profiles running perpendicu-
larly to the long side frame. An additional sup-
port bar should be placed below the module.
Use two clamps on the support bar.
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa
PW60HT-CP
Use two insertion profiles running parallel to
the long side frame.
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 4000 Pa
Use two insertion profiles running perpendicu-
larly to the long side frame. An additional sup-
port bar should be placed below the module.
Use two clamps on the support bar.
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 5400 Pa