![PHOTOWATT PW60HT-C-XF Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/photowatt/pw60ht-c-xf/pw60ht-c-xf_installation-manual_1553649020.webp)
D69-P06-01 GB R6
01/07/2020
www.photowatt.com
19
Use two clamps on the long side and two clamps
on the short side. Mounting rails run perpendi-
cular to the long side frame.
A1 range = (100 – 550) mm
A2 range = (200 – 250) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 2400 Pa
PW72LHT-C
Use four clamps on the long side. Mounting rails
run perpendicularly to the long side frame.
A1 range = (340 – 550) mm
Maximum Load:
Uplift load ≤ 2400 Pa
Downforce load ≤ 2400 Pa
A1 range = (410 – 490) mm
Maximum Load:
Uplift load ≤ 3600 Pa
Downforce load ≤ 5400 Pa