![Photon Focus OEM-D1024E Скачать руководство пользователя страница 57](http://html1.mh-extra.com/html/photon-focus/oem-d1024e/oem-d1024e_user-manual_1553518057.webp)
5.4
Trigger
5.4.1
Trigger Modes
The following sections show the timing diagram for the trigger modes. The signal
ExSync
denotes the trigger signal that is provided either by the interface trigger or the I/O trigger (see
Section 4.7). The other signals are explained in Table 5.6.
Camera module controlled Exposure
In the camera module controlled trigger mode, the exposure is defined by the camera module
and is configurable by software. For an active high trigger signal, the image acquisition begins
with the rising edge of the trigger signal. The image is read out after the pre-configured
exposure time. After the readout, the sensor returns to the reset state and the camera module
waits for a new trigger pulse (see Fig. 5.7).
The data is output on the rising edge of the pixel clock, the handshaking signals
FRAME_VALID
(
FVAL
) and
LINE_VALID
(
LVAL
) mask valid image information. The signal
SHUTTER
in Fig. 5.7
indicates the active integration phase of the sensor and is shown for clarity only.
P C L K
S H U T T E R
F V A L
L V A L
D V A L
D A T A
L i n e p a u s e
L i n e p a u s e
L i n e p a u s e
F i r s t L i n e
L a s t L i n e
E x p o s u r e
T i m e
F r a m e T i m e
E X S Y N C
C P R E
Figure 5.7: Trigger timing diagram for camera module controlled exposure
5.4 Trigger
55
Содержание OEM-D1024E
Страница 1: ...User Manual OEM D752E and OEM D1024E CMOS Sensor Module Series MAN032 04 2012 V1 2...
Страница 2: ......
Страница 4: ...2...
Страница 10: ...2 Introduction and Motivation 8...
Страница 18: ...3 OEM Specification 16...
Страница 46: ...4 Functionality 44...
Страница 66: ...7 Warranty 64...
Страница 68: ...8 References 66...