![Photon Focus OEM-D1024E Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/photon-focus/oem-d1024e/oem-d1024e_user-manual_1553518030.webp)
4 Functionality
4.3.4
Grey Level Transformation (LUT)
Grey level transformation is remapping of the grey level values of an input image to new
values. The look-up table (LUT) is used to convert the greyscale value of each pixel in an image
into another grey value. It is typically used to implement a transfer curve for contrast
expansion. The camera performs a 10-to-8-bit mapping, so that 1024 input grey levels can be
mapped to 256 output grey levels. The use of the three available modes is explained in the
next sections.
The output grey level resolution of the look-up table (independent of gain,
gamma or user-definded mode) is always 8 bit.
There are 2 predefined functions, which generate a look-up table and transfer it
to the camera. For other transfer functions the user can define his own LUT file.
Gain
The ’Gain’ mode performs a digital, linear amplification (see Fig. 4.17). It is configurable in the
range from 1.0 to 4.0 (e.g. 1.234).
0
200
400
600
800
1000
1200
0
50
100
150
200
250
300
Gray level transformation − Gain: y = (255/1023)
⋅
a
⋅
x
x: gray level input value (10 bit) [DN]
y: gray level output value (8 bit) [DN]
a = 1.0
a = 2.0
a = 3.0
a = 4.0
Figure 4.17: Applying a linear gain to an image
28
Содержание OEM-D1024E
Страница 1: ...User Manual OEM D752E and OEM D1024E CMOS Sensor Module Series MAN032 04 2012 V1 2...
Страница 2: ......
Страница 4: ...2...
Страница 10: ...2 Introduction and Motivation 8...
Страница 18: ...3 OEM Specification 16...
Страница 46: ...4 Functionality 44...
Страница 66: ...7 Warranty 64...
Страница 68: ...8 References 66...